Direct comparison of high voltage breakdown measurements in liquid argon and liquid xenon
arXiv:1908.06888 · doi:10.1088/1748-0221/14/12/P12018
Abstract
As noble liquid time projection chambers grow in size their high voltage requirements increase, and detailed, reproducible studies of dielectric breakdown and the onset of electroluminescence are needed to inform their design. The Xenon Breakdown Apparatus (XeBrA) is a 5-liter cryogenic chamber built to characterize the DC high voltage breakdown behavior of liquid xenon and liquid argon. Electrodes with areas up to 33~cm were tested while varying the cathode-anode separation from 1 to 6~mm with a voltage difference up to 75~kV. A power-law relationship between breakdown field and electrode area was observed. The breakdown behavior of liquid argon and liquid xenon within the same experimental apparatus was comparable.
References in corpus (14)
- DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
- Liquid noble gas detectors for low energy particle physics
- Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay
- Solar neutrino detection in a large volume double-phase liquid argon experiment
- Renormalization group theory for finite-size scaling in extreme statistics
- Study and mitigation of spurious electron emission from cathodic wires in noble liquid time projection chambers
- Experimental study of electric breakdowns in liquid argon at centimeter scale
- High Voltage in Noble Liquids for High Energy Physics
- On the Electric Breakdown in Liquid Argon at Centimeter Scale
- Liquid Argon Dielectric Breakdown Studies with the MicroBooNE Purification System
- An apparatus for studying electrical breakdown in liquid helium at 0.4 K and testing electrode materials for the SNS nEDM experiment
- A method to suppress dielectric breakdowns in liquid argon ionization detectors for cathode to ground distances of several millimeters
- Sub-GeV Dark Matter Searches and Electric Field Studies for the LUX and LZ Experiments
- High Voltage Test Apparatus for a Neutron EDM Experiment and Lower Limit on the Dielectric Strength of Liquid Helium at Large Volumes
Cited by in corpus (9)
- Electroluminescence and electron avalanching in two-phase detectors
- Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches
- Neutral bremsstrahlung electroluminescence in noble liquids
- Dielectric Strength of Noble and Quenched Gases for High Pressure Time Projection Chambers
- Design and construction of Xenoscope -- a full-scale vertical demonstrator for the DARWIN observatory
- A study of DC electrical breakdown in liquid helium through analysis of the empirical breakdown field distributions
- The Electric Field Dependence of Single Electron Emission in the PIXeY Two-Phase Xenon Detector
- Study of dielectric breakdown in liquid xenon with the XeBrA experiment
- Development & Characterization of Electrodes for large-scale Xenon Time Projection Chambers