Study of dielectric breakdown in liquid xenon with the XeBrA experiment
arXiv:2206.07854 · doi:10.1063/5.0107082
Abstract
Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding one meter, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a five-liter, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. In this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both anode current and photon rate was observed in the last 30 seconds leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler-Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.
arXiv comment18 pages, 16 figures; A typo in the author list was corrected; Corrections to the body text were made and supplementary material was added
References in corpus (16)
- DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
- Dark Matter Search Results from the PandaX-4T Commissioning Run
- DARWIN: towards the ultimate dark matter detector
- Search for New Physics in Electronic Recoil Data from XENONnT
- Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay
- Paschen's law studies in cold gases
- Study and mitigation of spurious electron emission from cathodic wires in noble liquid time projection chambers
- A simple high-sensitivity technique for purity analysis of xenon gas
- High Voltage in Noble Liquids for High Energy Physics
- On the Electric Breakdown in Liquid Argon at Centimeter Scale
- Direct comparison of high voltage breakdown measurements in liquid argon and liquid xenon
- Measurements of Angle-Resolved Reflectivity of PTFE in Liquid Xenon with IBEX
- A study of DC electrical breakdown in liquid helium through analysis of the empirical breakdown field distributions
- Study of background from accidental coincidence signals in the PandaX-II experiment
- Sub-GeV Dark Matter Searches and Electric Field Studies for the LUX and LZ Experiments
- Measurement of the Angular Distribution of Wavelength-Shifted Light Emitted by TPB