Potentialities of the future technical improvements in the search of rare nuclear decays by bolometers
arXiv:1802.04260 · doi:10.1142/S0217751X18430030
Abstract
Bolometers are cryogenic calorimeters which feature excellent energy resolution, low energy threshold, high detection efficiency, flexibility in choice of materials, particle identification capability if operated as hybrid devices. After thirty years of rapid progresses, they represent nowadays a leading technology in several fields: particle and nuclear physics, X-ray astrophysics, cosmology. However, further and substantial developments are required to increase the sensitivity to the levels envisioned by future researches. A review of the challenges to be addressed and potentialities of bolometers in the search for rare nuclear decays is given, with particular emphasis to the neutrinoless double beta decay physics case.
References in corpus (75)
- Big-Bang Nucleosynthesis
- Results from 730 kg days of the CRESST-II Dark Matter Search
- Search for Low-Mass WIMPs with SuperCDMS
- Neutrinoless double beta decay: 2015 review
- WIMP-Search Results from the Second CDMSlite Run
- Results on light dark matter particles with a low-threshold CRESST-II detector
- First Results from CUORE: A Search for Lepton Number Violation via Decay of Te
- 130Te Neutrinoless Double-Beta Decay with CUORICINO
- Value of the axial-vector coupling strength in and decays: A review
- Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
- ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging Spectrophotometer
- Results on low mass WIMPs using an upgraded CRESST-II detector
- A dual-band millimeter-wave kinetic inductance camera for the IRAM 30-meter telescope
- Searching for neutrinoless double-beta decay of Te with CUORE
- Average and recommended half-life values for two neutrino double beta decay
- Scintillating double beta decay bolometers
- Development of Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
- The projected background for the CUORE experiment
- Discovery probability of next-generation neutrinoless double- decay experiments
- Neutrino-less Double Electron Capture - a tool to research for Majorana neutrinos
- Masses of 130Te, 130Xe and double-beta-decay Q-value of 130Te
- High-speed phonon imaging using frequency-multiplexed kinetic inductance detectors
- Potential of a next generation neutrinoless double beta decay experiment based on ZnMoO4 scintillating bolometers
- Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum
- Detection of the Natural Alpha Decay of Tungsten
- The COSINUS project - perspectives of a NaI scintillating calorimeter for dark matter search
- Performances of a large mass ZnSe bolometer to search for rare events
- Double-beta decay Q values of 130Te, 128Te, and 120Te
- CdWO4 scintillating bolometer for Double Beta Decay: Light and Heat anticorrelation, light yield and quenching factors
- Characterization of ZnSe scintillating bolometers for Double Beta Decay
- Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
- Performances of a large mass ZnMoO4 scintillating bolometer for a next generation neutrinoless double beta decay experiment
- ZnMoO4: a promising bolometer for neutrinoless double beta decay searches
- Initial performance of the CUORE-0 experiment
- CUORE-0 detector: design, construction and operation
- First array of enriched ZnSe bolometers to search for double beta decay
- CALDER - Neutrinoless double-beta decay identification in TeO bolometers with kinetic inductance detectors
- Impact of the quenching of on the sensitivity of experiments
- Characterization of bolometric Light Detectors for rare event searches
- High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array
- A novel technique of particle identification with bolometric detectors
- Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors
- Random coincidence of decay events as a background source in bolometric decay experiments
- TeO bolometers with Cherenkov signal tagging: towards next-generation neutrinoless double beta decay experiments
- A CaMoO4 Crystal Low Temperature Detector for the AMoRE Neutrinoless Double Beta Decay Search
- New experimental limits on the alpha decays of lead isotopes
- Low background techniques in bolometers for double-beta decay search
- Enriched TeO bolometers with active particle discrimination: towards the CUPID experiment
- Discovery of the Eu decay
- Energy resolution and efficiency of phonon-mediated Kinetic Inductance Detectors for light detection
- CUPID: CUORE (Cryogenic Underground Observatory for Rare Events) Upgrade with Particle IDentification
- First measurement of the partial widths of Bi decay to the ground and to the first excited states
- Discrimination of alpha and beta/gamma interactions in a TeO bolometer
- Scintillating bolometers for Double Beta Decay search
- The use of low temperature detectors for direct measurements of the mass of the electron neutrino
- Particle Discrimination in TeO Bolometers using Light Detectors read out by Transition Edge Sensors
- Complete event-by-event / separation in a full-size TeO CUORE bolometer by Neganov-Luke-magnified light detection
- High sensitivity phonon-mediated kinetic inductance detector with combined amplitude and phase read-out
- Background suppression in massive TeO bolometers with Neganov-Luke amplified light detectors
- Rejection of randomly coinciding events in LiMoO scintillating bolometers using light detectors based on the Neganov-Luke effect
- New Limits on Naturally Occurring Electron Capture of 123Te
- Simulations of background sources in AMoRE-I experiment
- Rejection of randomly coinciding events in ZnMoO scintillating bolometers
- A CsI low temperature detector for dark matter search
- Multiplexed readout of MMC detector arrays using non-hysteretic rf-SQUIDs
- Low-Temperature Light Detectors: Neganov-Luke Amplification and Calibration
- Neganov-Luke amplified cryogenic light detectors for the background discrimination in neutrinoless double beta decay search with TeO bolometers
- Model for the Cherenkov light emission of TeO cryogenic calorimeters
- Cerenkov light identification with Si low-temperature detectors with Neganov-Luke effect-enhanced sensitivity
- Pulse Shape Analysis with scintillating bolometers
- First test of an enriched CdWO scintillating bolometer for neutrinoless double-beta-decay searches
- Characterization of the KID-Based Light Detectors of CALDER
- Competition Between Particle-Hole and Particle-Particle Correlations in Forbidden Electron Capture: the Case of Te
- Measurements of the Cerenkov light emitted by a TeO2 crystal
- LUMINEU: a search for neutrinoless double beta decay based on ZnMoO scintillating bolometers
Cited by in corpus (11)
- Experimental searches for rare alpha and beta decays
- Analysis of cryogenic calorimeters with light and heat read-out for double beta decay searches
- Charge-to-heat transducers exploiting the Neganov-Trofimov-Luke effect for light detection in rare-event searches
- CUPID, the CUORE Upgrade with Particle IDentification
- Test of CdWO and LiMoO scintillating bolometers in the CROSS underground facility with upgraded detector suspension
- A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
- Search for Neutrino-less Double Beta Decay of Zn and Zn with CUPID-0
- Twelve-crystal prototype of LiMoO scintillating bolometers for CUPID and CROSS experiments
- LiMoO Scintillating Bolometers for Rare-Event Search Experiments
- BINGO innovative assembly for background reduction in bolometric experiments
- A CUPID LiMoO scintillating bolometer tested in the CROSS underground facility