Test of CdWO and LiMoO scintillating bolometers in the CROSS underground facility with upgraded detector suspension
arXiv:2307.14831 · doi:10.1088/1748-0221/18/12/P12004
Abstract
In preparation to the CROSS decay experiment, we installed a new detector suspension with magnetic dumping inside a pulse-tube cryostat of a dedicated low-background facility at the LSC (Spain). The suspension was tested with two scintillating bolometers based on large-volume 116CdWO4 (CWO-enr) and Li2MoO4 (LMO) crystals. The former, a reference device, was used for testing new noise conditions and for comparing bolometric performance of an advanced Li2MoO4 crystal developed in the framework of the CLYMENE project, in view of next-generation double-beta decay experiments like CUPID. We cooled down detectors to 15 mK and achieved high performance for all tested devices. In particular both CWO-enr and LMO bolometers demonstrated the energy resolution of 6 keV FWHM for the 2.6 MeV gamma quanta, among the best for thermal detectors based on such compounds. The baseline noise resolution (FWHM) of the CWO-enr detector was improved by 2 keV, compared to the best previous measurement of this detector in the CROSS facility, while the noise of the Ge-based optical bolometer was improved by a factor 2, to 100 eV FWHM. Despite of the evident progress in the improving of noise conditions of the set-up, we see high-frequency harmonics of a pulse-tube induced noise, suggesting a noise pick-up by cabling. Another Ge light detector was assisted with the signal amplification exploiting the Neganov-Trofimov-Luke effect, which allowed to reach 20 eV FWHM noise resolution by applying 60 V electrode bias. Highly-efficient particle identification was achieved with both detectors, despite a low scintillation efficiency of the LMO material. The radiopurity level of the LMO crystal is rather high; only traces of 210Po and 226Ra were detected (0.1 mBq/kg each), while the 228Th activity is expected to be at least an order of magnitude lower, as well as a 40K activity is found to be < 6 mBq/kg.
arXiv commentPrepared for submission to JINST, 26 pages, 8 figures, 2 tables
References in corpus (45)
- A Unified Approach to the Classical Statistical Analysis of Small Signals
- Neutrinoless Double-Beta Decay: Status and Prospects
- Toward the discovery of matter creation with neutrinoless double-beta decay
- Search for the Majorana Nature of Neutrinos in the Inverted Mass Ordering Region with KamLAND-Zen
- The event generator DECAY4 for simulation of double beta processes and decay of radioactive nuclei
- Scintillating double beta decay bolometers
- Development of Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
- The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects
- CdWO4 scintillating bolometer for Double Beta Decay: Light and Heat anticorrelation, light yield and quenching factors
- Development of a Li2MoO4 scintillating bolometer for low background physics
- CUPID-0: the first array of enriched scintillating bolometers for 0νββdecay investigations
- Characterization of bolometric Light Detectors for rare event searches
- Final results of the Aurora experiment to study 2 decay of Cd with enriched CdWO crystal scintillators
- Vibrations on pulse tube based Dry Dilution Refrigerators for low noise measurements
- Low background detector with enriched 116CdWO4 crystal scintillators to search for double beta decay of 116Cd
- Random coincidence of decay events as a background source in bolometric decay experiments
- Precise measurement of decay of Mo with the CUPID-Mo detection technology
- Improvement of radiopurity level of enriched CdWO and ZnWO crystal scintillators by recrystallization
- CUPID: CUORE (Cryogenic Underground Observatory for Rare Events) Upgrade with Particle IDentification
- First scintillating bolometer tests of a CLYMENE R&D on LiMoO scintillators towards a large-scale double-beta decay experiment
- Optimizing the energy threshold of light detectors coupled to luminescent bolometers
- Status and performance of the AMoRE-I experiment on neutrinoless double beta decay
- The -decay CROSS experiment: preliminary results and prospects
- Mo-enriched LiMoO scintillating bolometers for decay search: from LUMINEU to CUPID-0/Mo projects
- Charge-to-heat transducers exploiting the Neganov-Trofimov-Luke effect for light detection in rare-event searches
- Rejection of randomly coinciding events in LiMoO scintillating bolometers using light detectors based on the Neganov-Luke effect
- Radioactive contamination of scintillators
- Rejection of randomly coinciding events in ZnMoO scintillating bolometers
- Novel technique for the study of pile-up events in cryogenic bolometers
- A multi-isotope bolometric experiment
- Radiopure tungstate and molybdate crystal scintillators for double beta decay experiments
- Potentialities of the future technical improvements in the search of rare nuclear decays by bolometers
- First test of an enriched CdWO scintillating bolometer for neutrinoless double-beta-decay searches
- Probing the Mechanism of Neutrinoless Double-Beta Decay in Multiple Isotopes
- Systematic Analysis of Double-Beta Decay Half Lives
- Phonon-mediated crystal detectors with metallic film coating capable of rejecting and events induced by surface radioactivity
- Neutrinoless Double Beta Decay with Germanium Detectors: 10 yr and Beyond
- High resolution digitization system for the CROSS experiment
- High resolution filtering and digitization system for cryogenic bolometric detectors
- Twelve-crystal prototype of LiMoO scintillating bolometers for CUPID and CROSS experiments
- LiMoO Scintillating Bolometers for Rare-Event Search Experiments
- Neutrinoless Double Beta Decay
- Double Beta Decay Experiments at Canfranc Underground Laboratory
- The program Simourg for simulating the response functions of gamma detectors with simple geometries
- A CUPID LiMoO scintillating bolometer tested in the CROSS underground facility
Cited by in corpus (6)
- CUPID, the CUORE Upgrade with Particle IDentification
- A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment
- BINGO innovative assembly for background reduction in bolometric experiments
- Unfolding environmental flux spectrum with portable CZT detector
- Development of large-volume TeO bolometers for the CROSS decay search experiment
- Cryogenic light detectors with thermal signal amplification for search experiments