First test of an enriched CdWO scintillating bolometer for neutrinoless double-beta-decay searches
arXiv:1606.07806 · doi:10.1140/epjc/s10052-016-4331-2
Abstract
For the first time, a cadmium tungstate crystal scintillator enriched in Cd has been succesfully tested as a scintillating bolometer. The measurement was performed above ground at a temperature of 18 mK. The crystal mass was 34.5 g and the enrichment level ~82 %. Despite a substantial pile-up effect due to above-ground operation, the detector demonstrated a high energy resolution (2-7 keV FWHM in 0.2-2.6 MeV energy range), a powerful particle identification capability and a high level of internal radiopurity. These results prove that cadmium tungstate is an extremely promising detector material for a next-generation neutrinoless double-beta decay bolometric experiment, like that proposed in the CUPID project (CUORE Upgrade with Particle IDentification).
References in corpus (25)
- A Unified Approach to the Classical Statistical Analysis of Small Signals
- Search for Majorana Neutrinos near the Inverted Mass Hierarchy Region with KamLAND-Zen
- Theory of neutrinoless double beta decay
- Neutrinoless Double Beta Decay and Physics Beyond the Standard Model
- Semi-empirical calculation of quenching factors for ions in scintillators
- Neutrinoless double beta decay and neutrino physics
- Limits on the neutrino mass from neutrinoless double- decay
- Neutrinoless Double-Beta Decay: a Probe of Physics Beyond the Standard Model
- Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
- Average and recommended half-life values for two neutrino double beta decay
- Scintillating double beta decay bolometers
- Neutrinoless Double Beta Decay
- On the alpha activity of natural tungsten isotopes
- Potential of a next generation neutrinoless double beta decay experiment based on ZnMoO4 scintillating bolometers
- CdWO4 scintillating bolometer for Double Beta Decay: Light and Heat anticorrelation, light yield and quenching factors
- First array of enriched ZnSe bolometers to search for double beta decay
- Search for double beta decay processes in 106Cd with the help of 106CdWO4 crystal scintillator
- Low background detector with enriched 116CdWO4 crystal scintillators to search for double beta decay of 116Cd
- Enriched ZnMoO scintillating bolometers to search for decay of Mo with the LUMINEU experiment
- Improvement of radiopurity level of enriched CdWO and ZnWO crystal scintillators by recrystallization
- Search for decay of Cd with enriched CdWO crystal scintillator in coincidence with four HPGe detectors
- CdWO4 crystal scintillators from enriched isotopes for double beta decay experiments
- Search for double beta decay of Cd with enriched CdWO crystal scintillators (Aurora experiment)
- Response of CdWO4 crystal scintillator for few MeV ions and low energy electrons
- Search for 2β decay of 116Cd with the help of enriched 116CdWO4 crystal scintillators
Cited by in corpus (10)
- The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects
- Improvement of radiopurity level of enriched CdWO and ZnWO crystal scintillators by recrystallization
- Low background techniques in bolometers for double-beta decay search
- First scintillating bolometer tests of a CLYMENE R&D on LiMoO scintillators towards a large-scale double-beta decay experiment
- Radioactive contamination of scintillators
- Radiopure tungstate and molybdate crystal scintillators for double beta decay experiments
- Potentialities of the future technical improvements in the search of rare nuclear decays by bolometers
- Double Beta Decay APPEC Committee Report
- Test of CdWO and LiMoO scintillating bolometers in the CROSS underground facility with upgraded detector suspension
- First test of a scintillating bolometer for neutrinoless double beta decay experiments with and nuclides