Response of CdWO4 crystal scintillator for few MeV ions and low energy electrons
arXiv:1209.0015 · doi:10.1016/j.nima.2012.08.106
Abstract
The response of a CdWO4 crystal scintillator to protons, alpha particles, Li, C, O and Ti ions with energies in the range 1 - 10 MeV was measured. The non-proportionality of CdWO4 for low energy electrons (4 - 110 keV) was studied with the Compton Coincidence Technique. The energy dependence of the quenching factors for ions and the relative light yield for low energy electrons was calculated using a semi-empirical approach. Pulse-shape discrimination ability between gamma quanta, protons, alpha particles and ions was investigated.
20 pages, 8 figs, accepted in Nucl. Instrum. Meth. A
References in corpus (10)
- Dark Matter Candidates from Particle Physics and Methods of Detection
- First results from DAMA/LIBRA and the combined results with DAMA/NaI
- New results from DAMA/LIBRA
- Results from 730 kg days of the CRESST-II Dark Matter Search
- Further study of CdWO4 crystal scintillators as detectors for high sensitivity double beta experiments: scintillation properties and pulse-shape discrimination
- Search for double beta decay processes in 106Cd with the help of 106CdWO4 crystal scintillator
- Low background detector with enriched 116CdWO4 crystal scintillators to search for double beta decay of 116Cd
- Pulse-shape discrimination with PbWO crystal scintillators
- Direct Dark Matter Searches
- Scintillator Non-Proportionality and Gamma Quenching in CaWO4
Cited by in corpus (7)
- Experimental searches for rare alpha and beta decays
- Measurement of the proton light response of various LAB based scintillators and its implication for supernova neutrino detection via neutrino-proton scattering
- Measurements of ZnWO anisotropic response to nuclear recoils for the ADAMO project
- Radioactive contamination of scintillators
- First test of an enriched CdWO scintillating bolometer for neutrinoless double-beta-decay searches
- Semi-empirical calculation of quenching factors for scintillators: new results
- Digital Logarithmic Airborne Gamma Ray Spectrometer