CdWO4 scintillating bolometer for Double Beta Decay: Light and Heat anticorrelation, light yield and quenching factors
arXiv:1005.1239 · doi:10.1016/j.astropartphys.2010.06.009
Abstract
We report the performances of a 0.51 kg CdWO4 scintillating bolometer to be used for future Double Beta Decay Experiments. The simultaneous read-out of the heat and the scintillation light allows to discriminate between different interacting particles aiming at the disentanglement and the reduction of background contribution, key issue for next generation experiments. We will describe the observed anticorrelation between the heat and the light signal and we will show how this feature can be used in order to increase the energy resolution of the bolometer over the entire energy spectrum, improving up to a factor 2.6 on the 2615 keV line of 208Tl. The detector was tested in a 433 h background measurement that permitted to estimate extremely low internal trace contaminations of 232Th and 238U. The light yield of gamma/beta, alpha and neutrons is presented. Furthermore we developed a method in order to correctly evaluate the absolute thermal quenching factor of alpha particles in scintillating bolometers.
8 pages 7 figures
References in corpus (6)
- Double Beta Decay, Majorana Neutrinos, and Neutrino Mass
- Results from a search for the -decay of
- Semi-empirical calculation of quenching factors for ions in scintillators
- Commissioning Run of the CRESST-II Dark Matter Search
- Measurement of the background in the NEMO 3 double beta decay experiment
- Measurement of the response of heat-and-ionization germanium detectors to nuclear recoils
Cited by in corpus (37)
- Results on light dark matter particles with a low-threshold CRESST-II detector
- Development of Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
- Potential of a next generation neutrinoless double beta decay experiment based on ZnMoO4 scintillating bolometers
- Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum
- The COSINUS project - perspectives of a NaI scintillating calorimeter for dark matter search
- Performances of a large mass ZnSe bolometer to search for rare events
- Characterization of ZnSe scintillating bolometers for Double Beta Decay
- Development of a Li2MoO4 scintillating bolometer for low background physics
- CALDER - Neutrinoless double-beta decay identification in TeO bolometers with kinetic inductance detectors
- Characterization of bolometric Light Detectors for rare event searches
- A novel technique of particle identification with bolometric detectors
- New experimental limits on the alpha decays of lead isotopes
- Low background techniques in bolometers for double-beta decay search
- First measurement of the partial widths of Bi decay to the ground and to the first excited states
- Optimizing the energy threshold of light detectors coupled to luminescent bolometers
- Radioactive contamination of scintillators
- Rejection of randomly coinciding events in ZnMoO scintillating bolometers
- Optimization of light collection from crystal scintillators for cryogenic experiments
- Purification of molybdenum oxide, growth and characterization of medium size zinc molybdate crystals for the LUMINEU program
- A multi-isotope bolometric experiment
- Radiopure tungstate and molybdate crystal scintillators for double beta decay experiments
- Potentialities of the future technical improvements in the search of rare nuclear decays by bolometers
- Pulse Shape Analysis with scintillating bolometers
- First test of an enriched CdWO scintillating bolometer for neutrinoless double-beta-decay searches
- Application of the Monte-Carlo refractive index matching (MCRIM) technique to the determination of the absolute light yield of a calcium molybdate scintillator
- In-situ study of light production and transport in phonon/light detector modules for dark matter search
- Test of CdWO and LiMoO scintillating bolometers in the CROSS underground facility with upgraded detector suspension
- Semi-empirical calculation of quenching factors for scintillators: new results
- Experimental searches of neutrinoless double beta decay
- Performance of a large TeO2 crystal as a cryogenic bolometer in searching for neutrinoless double beta decay
- Resolution enhancement with light/heat decorrelation in CUPID-0 bolometric detector
- Cryogenic phonon-scintillation detectors with PMT readout for rare event search experiments
- ZnO-based scintillating bolometers: New prospects to study double beta decay of Zn
- A custom experimental setup for scintillator characterization: application to a Ce-doped GAGG crystal
- Aboveground test of an advanced LiMoO scintillating bolometer to search for neutrinoless double beta decay of Mo
- CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
- Rejection of randomly coinciding 2ν2β events in ZnMoO4 scintillating bolometers