Characterization of ZnSe scintillating bolometers for Double Beta Decay
arXiv:1006.2721 · doi:10.1016/j.astropartphys.2010.09.004
Abstract
ZnSe scintillating bolometers are good candidates for future Double Beta Decay searches, because of the 82Se high Q-value and thanks to the possibility of alpha background rejection on the basis of the scintillation signal. In this paper we report the characteristics and the anomalies observed in an extensive study of these devices. Among them, an unexpected high emission from alpha particles, accompanied with an unusual pattern of the light vs. heat scatter plot. The perspectives for the application of this kind of detectors to search for the Neutrinoless Double Beta Decay of 82Se are presented.
12 pages, 10 figures
References in corpus (19)
- Double Beta Decay, Majorana Neutrinos, and Neutrino Mass
- Double Beta Decay
- Disassembling the Nuclear Matrix Elements of the Neutrinoless double beta Decay
- Anatomy of nuclear matrix elements for neutrinoless double-beta decay
- CUORE: A Cryogenic Underground Observatory for Rare Events
- Detection of very small neutrino masses in double-beta decay using laser tagging
- Results from a search for the -decay of
- First results of the search of neutrinoless double beta decay with the NEMO 3 detector
- Technical design and performance of the NEMO3 detector
- Measurements of extremely low radioactivity levels in BOREXINO
- Scintillating double beta decay bolometers
- On the alpha activity of natural tungsten isotopes
- A New Limit on the Neutrinoless DBD of 130Te
- CdWO4 scintillating bolometer for Double Beta Decay: Light and Heat anticorrelation, light yield and quenching factors
- Physics Potential and Prospects for the CUORICINO and CUORE Experiments
- Scintillating bolometers for Double Beta Decay search
- The Neutrinoless Double Beta Decay: The Case for Germanium Detectors
- Muon-induced backgrounds in the CUORICINO experiment
- Pulse shapes from electron and photon induced events in segmented high-purity germanium detectors
Cited by in corpus (32)
- Colloquium: Majorana Fermions in nuclear, particle and solid-state physics
- Potential of a next generation neutrinoless double beta decay experiment based on ZnMoO4 scintillating bolometers
- Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum
- First Result on the Neutrinoless Double Beta Decay of Se with CUPID-0
- Performances of a large mass ZnSe bolometer to search for rare events
- Recent Progress in Double Beta Decay
- First array of enriched ZnSe bolometers to search for double beta decay
- Characterization of bolometric Light Detectors for rare event searches
- A novel technique of particle identification with bolometric detectors
- Random coincidence of decay events as a background source in bolometric decay experiments
- Evidence of Single State Dominance in the Two-Neutrino Double- Decay of Se-82 with CUPID-0
- Low background techniques in bolometers for double-beta decay search
- Double-beta decay investigation with highly pure enriched Se for the LUCIFER experiment
- First measurement of the partial widths of Bi decay to the ground and to the first excited states
- Analysis of cryogenic calorimeters with light and heat read-out for double beta decay searches
- Optimizing the energy threshold of light detectors coupled to luminescent bolometers
- Radioactive contamination of scintillators
- Search of the neutrino-less double beta decay of Se into the excited states of Kr with CUPID-0
- A CsI low temperature detector for dark matter search
- Optimization of light collection from crystal scintillators for cryogenic experiments
- Radiopure tungstate and molybdate crystal scintillators for double beta decay experiments
- Potentialities of the future technical improvements in the search of rare nuclear decays by bolometers
- Pulse Shape Analysis with scintillating bolometers
- Particle detection at cryogenic temperatures with undoped CsI
- Effect of SiO2 coating in bolometric Ge light detectors for rare event searches
- Application of the Monte-Carlo refractive index matching (MCRIM) technique to the determination of the absolute light yield of a calcium molybdate scintillator
- Performance of a large TeO2 crystal as a cryogenic bolometer in searching for neutrinoless double beta decay
- Performance of ZnSe-based scintillators at low temperatures
- First test of a scintillating bolometer for neutrinoless double beta decay experiments with and nuclides
- CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
- Search for Sterile Neutrinos with CUPID-0
- Cryogenic sensor enabling broad-band and traceable power measurements