Scintillating double beta decay bolometers
arXiv:nucl-ex/0510074 · doi:10.1134/S1063778806120155
Abstract
We present the results obtained in the development of scintillating Double Beta Decay bolometers. Several Mo and Cd based crystals were tested with the bolometric technique. The scintillation light was measured through a second independent bolometer. A 140 g CdWO_4 crystal was run in a 417 h live time measurement. Thanks to the scintillation light, the alpha background is easily discriminated resulting in zero counts above the 2615 keV gamma line of Thallium 208. These results, combined with an extremely easy light detector operation, represent the first tangible proof demonstrating the feasibility of this kind of technique.
15 pages, 8 figures
References in corpus (3)
Cited by in corpus (60)
- Performance of scintillation materials at cryogenic temperatures
- Development of Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
- Development of CaMoO4 crystal scintillators for double beta decay experiment with 100-Mo
- The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects
- Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum
- First Result on the Neutrinoless Double Beta Decay of Se with CUPID-0
- Performances of a large mass ZnSe bolometer to search for rare events
- New Limit for Neutrinoless Double-Beta Decay of Mo from the CUPID-Mo Experiment
- CdWO4 scintillating bolometer for Double Beta Decay: Light and Heat anticorrelation, light yield and quenching factors
- Final result of CUPID-0 phase-I in the search for the Se Neutrinoless Double Beta Decay
- Characterization of ZnSe scintillating bolometers for Double Beta Decay
- Development of a Li2MoO4 scintillating bolometer for low background physics
- Performances of a large mass ZnMoO4 scintillating bolometer for a next generation neutrinoless double beta decay experiment
- ZnMoO4: a promising bolometer for neutrinoless double beta decay searches
- First array of enriched ZnSe bolometers to search for double beta decay
- A novel technique of particle identification with bolometric detectors
- Random coincidence of decay events as a background source in bolometric decay experiments
- Evidence of Single State Dominance in the Two-Neutrino Double- Decay of Se-82 with CUPID-0
- Enriched ZnMoO scintillating bolometers to search for decay of Mo with the LUMINEU experiment
- Final Result on the Neutrinoless Double Beta Decay of Se with CUPID-0
- A CaMoO4 Crystal Low Temperature Detector for the AMoRE Neutrinoless Double Beta Decay Search
- Low background techniques in bolometers for double-beta decay search
- Enriched TeO bolometers with active particle discrimination: towards the CUPID experiment
- Production of 82Se enriched Zinc Selenide (ZnSe) crystals for the study of neutrinoless double beta decay
- Discrimination of alpha and beta/gamma interactions in a TeO bolometer
- Analysis of cryogenic calorimeters with light and heat read-out for double beta decay searches
- Scintillating bolometers for Double Beta Decay search
- Optimizing the energy threshold of light detectors coupled to luminescent bolometers
- The -decay CROSS experiment: preliminary results and prospects
- AMoRE: A search for neutrinoless double-beta decay of 100Mo using low-temperature molybdenum-containing crystal detectors
- Temperature dependence of scintillation properties of SrMoO4
- Rejection of randomly coinciding events in LiMoO scintillating bolometers using light detectors based on the Neganov-Luke effect
- Charge-to-heat transducers exploiting the Neganov-Trofimov-Luke effect for light detection in rare-event searches
- Radioactive contamination of scintillators
- Search of the neutrino-less double beta decay of Se into the excited states of Kr with CUPID-0
- Rejection of randomly coinciding events in ZnMoO scintillating bolometers
- Cryogenic light detectors with enhanced performance for rare events physics
- Purification of molybdenum oxide, growth and characterization of medium size zinc molybdate crystals for the LUMINEU program
- A multi-isotope bolometric experiment
- Model for the Cherenkov light emission of TeO cryogenic calorimeters
- CUPID, the CUORE Upgrade with Particle IDentification
- First test of an enriched CdWO scintillating bolometer for neutrinoless double-beta-decay searches
- Pulse Shape Analysis with scintillating bolometers
- Potentialities of the future technical improvements in the search of rare nuclear decays by bolometers
- Effect of SiO2 coating in bolometric Ge light detectors for rare event searches
- Phonon-mediated crystal detectors with metallic film coating capable of rejecting and events induced by surface radioactivity
- Search for Neutrino-less Double Beta Decay of Zn and Zn with CUPID-0
- Background identification in cryogenic calorimeters through delayed coincidences
- A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
- Test of CdWO and LiMoO scintillating bolometers in the CROSS underground facility with upgraded detector suspension
- Twelve-crystal prototype of LiMoO scintillating bolometers for CUPID and CROSS experiments
- LiMoO Scintillating Bolometers for Rare-Event Search Experiments
- Performance of a large TeO2 crystal as a cryogenic bolometer in searching for neutrinoless double beta decay
- The CROSS Experiment: Rejecting Surface Events by PSD Induced by Superconducting Films
- Li-containing scintillating bolometers for low background physics
- BINGO innovative assembly for background reduction in bolometric experiments
- Counting photons at low temperature with a streaming time-to-digital converter
- Rejection of randomly coinciding 2ν2β events in ZnMoO4 scintillating bolometers
- Search for Sterile Neutrinos with CUPID-0
- Cryogenic light detectors with thermal signal amplification for search experiments