Cryogenic light detectors with enhanced performance for rare events physics
arXiv:1901.11009 · doi:10.1016/j.nima.2019.05.019
Abstract
We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward mounting results in three important improvements: (1) it decreases the amount of non-active materials needed to assemble the detector, (2) it substantially increases the light collection efficiency by minimizing the light losses induced by the mounting structure, and (3) it enhances the thermal signal induced in the light detector thanks to the extremely weak thermal link to the thermal bath. We tested this new technique with a 16 cm Ge light detector with thermistor readout sitting on the surface of a large TeO bolometer. The light collection efficiency was increased by greater than 50\% compared to previously tested alternative mountings. We obtained a baseline energy resolution on the light detector of 20~eV RMS that, together with increased light collection, enabled us to obtain the best vs discrimination ever obtained with massive TeO crystals. At the same time we achieved rise and decay times of 0.8 and 1.6 ms, respectively. This superb performance meets all of the requirements for the CUPID (CUORE Upgrade with Particle IDentification) experiment, which is a 1-ton scintillating bolometer follow up to CUORE.
6 pages, 4 figures
References in corpus (6)
- Random coincidence of decay events as a background source in bolometric decay experiments
- TeO bolometers with Cherenkov signal tagging: towards next-generation neutrinoless double beta decay experiments
- Enriched TeO bolometers with active particle discrimination: towards the CUPID experiment
- Particle Discrimination in TeO Bolometers using Light Detectors read out by Transition Edge Sensors
- Neganov-Luke amplified cryogenic light detectors for the background discrimination in neutrinoless double beta decay search with TeO bolometers
- R&D towards CUPID (CUORE Upgrade with Particle IDentification)