Neganov-Luke amplified cryogenic light detectors for the background discrimination in neutrinoless double beta decay search with TeO bolometers
arXiv:1407.6516 · doi:10.1088/1748-0221/10/03/P03003
Abstract
We demonstrate that Neganov-Luke amplified cryogenic light detectors with Transition Edge Sensor read-out can be applied for the background suppression in cryogenic experiments searching for the neutrinoless double beta decay of with TeO based bolometers. Electron and gamma induced events can be discriminated from events by detecting the Cherenkov light produced by the particles emitted in the decay. We use the Cherenkov light produced by events in the full energy peak of and by events from a source to show that at the Q-value of the neutrinoless double beta decay of (), a separation of events from events can be achieved on an event-by-event basis with practically no reduction in signal acceptance.
arXiv comment10 pages, 4 figures, revision for submission to JINST
References in corpus (9)
- Results from 730 kg days of the CRESST-II Dark Matter Search
- CUORE: A Cryogenic Underground Observatory for Rare Events
- Commissioning Run of the CRESST-II Dark Matter Search
- Detection of the Natural Alpha Decay of Tungsten
- Initial performance of the CUORE-0 experiment
- TeO bolometers with Cherenkov signal tagging: towards next-generation neutrinoless double beta decay experiments
- Discrimination of alpha and beta/gamma interactions in a TeO bolometer
- Optimization of light collection from crystal scintillators for cryogenic experiments
- Low-Temperature Light Detectors: Neganov-Luke Amplification and Calibration
Cited by in corpus (13)
- First array of enriched ZnSe bolometers to search for double beta decay
- CALDER - Neutrinoless double-beta decay identification in TeO bolometers with kinetic inductance detectors
- Low background techniques in bolometers for double-beta decay search
- Enriched TeO bolometers with active particle discrimination: towards the CUPID experiment
- Complete event-by-event / separation in a full-size TeO CUORE bolometer by Neganov-Luke-magnified light detection
- High sensitivity phonon-mediated kinetic inductance detector with combined amplitude and phase read-out
- Performance of a Large Area Photon Detector For Rare Event Search Applications
- Charge-to-heat transducers exploiting the Neganov-Trofimov-Luke effect for light detection in rare-event searches
- The saga of neutrinoless double beta decay search with TeO2 thermal detectors
- Cryogenic light detectors with enhanced performance for rare events physics
- Cerenkov light identification with Si low-temperature detectors with Neganov-Luke effect-enhanced sensitivity
- Potentialities of the future technical improvements in the search of rare nuclear decays by bolometers
- New application of superconductors: high sensitivity cryogenic light detectors