Initial performance of the CUORE-0 experiment
arXiv:1402.0922 · doi:10.1140/epjc/s10052-014-2956-6
Abstract
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-dominated region (2.70 to 3.90 MeV) have been measured to be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7 keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.
8 pages, 5 figures, version 2 as published in Eur. Phys. J. C
References in corpus (9)
- Double Beta Decay, Majorana Neutrinos, and Neutrino Mass
- Phase space factors for double- decay
- Search for Neutrinoless Double-Beta Decay in Xe with EXO-200
- Energy density functional study of nuclear matrix elements for neutrinoless decay
- Nuclear matrix elements for double-β decay
- Double-beta decay Q values of 130Te, 128Te, and 120Te
- Two-neutrino double beta decay of deformed nuclei within QRPA with realistic interaction
- Validation of techniques to mitigate copper surface contamination in CUORE
- Noise correlation and decorrelation in arrays of bolometric detectors
Cited by in corpus (35)
- Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
- Searching for neutrinoless double-beta decay of Te with CUORE
- Development of Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
- First Results from the AMoRE-Pilot neutrinoless double beta decay experiment
- Measurement of the Two-Neutrino Double Beta Decay Half-life of Te with the CUORE-0 Experiment
- Mixing angle and phase correlations from A5 with generalised CP and their prospects for discovery
- Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in Te with CUORE-0
- CUORE-0 detector: design, construction and operation
- Effective Majorana mass matrix from tau and pseudoscalar meson lepton number violating decays
- CALDER - Neutrinoless double-beta decay identification in TeO bolometers with kinetic inductance detectors
- Enriched TeO bolometers with active particle discrimination: towards the CUPID experiment
- Double-beta decay investigation with highly pure enriched Se for the LUCIFER experiment
- Particle Discrimination in TeO Bolometers using Light Detectors read out by Transition Edge Sensors
- Complete event-by-event / separation in a full-size TeO CUORE bolometer by Neganov-Luke-magnified light detection
- Cryogenic light detectors with enhanced performance for rare events physics
- Neganov-Luke amplified cryogenic light detectors for the background discrimination in neutrinoless double beta decay search with TeO bolometers
- Radon mitigation during the installation of the CUORE decay detector
- The detector calibration system for the CUORE cryogenic bolometer array
- Search for Neutrinoless Decay of Te with CUORE-0
- Model for the Cherenkov light emission of TeO cryogenic calorimeters
- Potentialities of the future technical improvements in the search of rare nuclear decays by bolometers
- Constraints on the Active and Sterile Neutrino Masses from Beta-Ray Spectra: Past, Present and Future
- Status of double beta decay experiments using isotopes other than Xe-136
- CP violations in a predictive symmetry model
- Study of neutron-induced background and its effect on the search of 0 decay in
- Present status of neutrinoless double beta decay searches
- Cryogenic silicon detectors with implanted contacts for the detection of visible photons using the Neganov-Luke Effect
- An assembly line for the construction of ultra-pure detectors
- Mechanical Sensors for Ultraheavy Dark Matter Searches via Long-range Forces
- Connecting Majorana phases to the Geometric Parameters of Majorana Unitarity Triangle in a model of Neutrino Mass Matrix
- The CUORE and CUORE-0 Experiments at Gran Sasso
- Silicon PIN diodes as Neganov-Trofimov-Luke cryogenic light detectors
- CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
- Novel coincidence detection technique for precision measurement of neutron-capture-induced nuclear recoils
- CUORE-0 results and prospects for the CUORE experiment