CUORE-0 detector: design, construction and operation
arXiv:1604.05465 · doi:10.1088/1748-0221/11/07/P07009
Abstract
The CUORE experiment will search for neutrinoless double-beta decay of Te with an array of 988 TeO bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.
arXiv comment39 pages, 26 figures
References in corpus (17)
- Theory of neutrinoless double beta decay
- Results on neutrinoless double beta decay of 76Ge from GERDA Phase I
- Search for Majorana neutrinos with the first two years of EXO-200 data
- Limit on Neutrinoless ββ Decay of Xe-136 from the First Phase of KamLAND-Zen and Comparison with the Positive Claim in Ge-76
- 130Te Neutrinoless Double-Beta Decay with CUORICINO
- Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
- Searching for neutrinoless double-beta decay of Te with CUORE
- Masses of 130Te, 130Xe and double-beta-decay Q-value of 130Te
- A Calorimetric Search on Double Beta Decay of 130Te
- Production of high purity TeO2 single crystals for the study of neutrinoless double beta decay
- Double-beta decay Q values of 130Te, 128Te, and 120Te
- Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in Te with CUORE-0
- Validation of techniques to mitigate copper surface contamination in CUORE
- Initial performance of the CUORE-0 experiment
- CUORE crystal validation runs: results on radioactive contamination and extrapolation to CUORE background
- Muon-induced backgrounds in the CUORICINO experiment
- Cosmogenic-neutron activation of TeO2 and implications for neutrinoless double-beta decay experiments
Cited by in corpus (38)
- Neutrinoless Double-Beta Decay: Status and Prospects
- First Results from CUORE: A Search for Lepton Number Violation via Decay of Te
- Improved limit on neutrinoless double beta decay of Ge from GERDA Phase II
- Improved Limit on Neutrinoless Double-Beta Decay in Te with CUORE
- Neutrino Mass Ordering from Oscillations and Beyond: 2018 Status and Future Prospects
- Inelastic Boosted Dark Matter at Direct Detection Experiments
- The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
- Background Model of the CUPID-0 Experiment
- The front-end electronics system for the CUORE experiment
- An active noise cancellation technique for the CUORE Pulse Tube Cryocoolers
- Low background techniques in bolometers for double-beta decay search
- Enriched TeO bolometers with active particle discrimination: towards the CUPID experiment
- Measurement of the 2 Decay Half-life of Te with CUORE
- Identification of Pb and Po in the bulk of copper samples with a low-background alpha particle counter
- The saga of neutrinoless double beta decay search with TeO2 thermal detectors
- Novel technique for the study of pile-up events in cryogenic bolometers
- Radon mitigation during the installation of the CUORE decay detector
- High sensitivity characterization of an ultra-high purity NaI(Tl) crystal scintillator with the SABRE proof-of-principle detector
- Double-beta decay of Te to the first excited state of Xe with CUORE-0
- CUPID, the CUORE Upgrade with Particle IDentification
- Search for Neutrinoless Decay of Te with CUORE-0
- Potentialities of the future technical improvements in the search of rare nuclear decays by bolometers
- High-resolution for IAXO: MMC-based X-ray Detectors
- A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
- Simulation-based design study for the passive shielding of the COSINUS dark matter experiment
- An innovative technique for the investigation of the 4-fold forbidden beta-decay of V
- Testing spontaneous collapse through bulk heating experiments: estimate of the background noise
- Thermal conductivity measurements of PTFE and AlO ceramic at sub-Kelvin temperatures
- A laser interferometer accelerometer for vibration sensitive cryogenic experiments
- An automated system to define the optimal operating settings of cryogenic calorimeters
- A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment
- BINGO innovative assembly for background reduction in bolometric experiments
- The environmental low-frequency background for macro-calorimeters at the millikelvin scale
- The CUORE and CUORE-0 experiments at LNGS
- CUORE Opens the Door to Tonne-scale Cryogenics Experiments
- Fermion masses and mixings in a model based on the discrete symmetry
- High-Dimensional Bayesian Likelihood Normalisation for CRESST's Background Model
- Uncertainties in tellurium-based dark matter searches stemming from nuclear structure uncertainties