CUORE Opens the Door to Tonne-scale Cryogenics Experiments
arXiv:2108.07883 · doi:10.1016/j.ppnp.2021.103902
Abstract
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
arXiv comment45 pages, 14 figures
References in corpus (96)
- Supplementary information for "Quantum supremacy using a programmable superconducting processor"
- Dark Matter Search Results from a One TonneYear Exposure of XENON1T
- Results from a search for dark matter in the complete LUX exposure
- Neutrino Physics with JUNO
- New CAST Limit on the Axion-Photon Interaction
- Observation of Coherent Elastic Neutrino-Nucleus Scattering
- New experimental approaches in the search for axion-like particles
- Neutrinoless Double-Beta Decay: Status and Prospects
- WIMP dark matter candidates and searches - current status and future prospects
- First results from the CRESST-III low-mass dark matter program
- Excess Electronic Recoil Events in XENON1T
- A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron
- Supernova Neutrino Detection
- Fluctuations of Energy-Relaxation Times in Superconducting Qubits
- Conceptual Design of the International Axion Observatory (IAXO)
- First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
- DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon
- First Results from CUORE: A Search for Lepton Number Violation via Decay of Te
- Correlated Charge Noise and Relaxation Errors in Superconducting Qubits
- Relaxation and frequency shifts induced by quasiparticles in superconducting qubits
- Exclusion Limits on the WIMP-Nucleon Cross-Section from the Cryogenic Dark Matter Search
- 130Te Neutrinoless Double-Beta Decay with CUORICINO
- Impact of ionizing radiation on superconducting qubit coherence
- Results from a search for the -decay of
- Axion Dark Matter Detection using an LC Circuit
- First germanium-based constraints on sub-MeV Dark Matter with the EDELWEISS experiment
- Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes
- Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
- Improved Limit on Neutrinoless Double-Beta Decay in Te with CUORE
- Q value of the 100Mo Double-Beta Decay
- Searching for neutrinoless double-beta decay of Te with CUORE
- Reducing the impact of radioactivity on quantum circuits in a deep-underground facility
- First Axion Results from the XENON100 Experiment
- HOLMES - The Electron Capture Decay of 163Ho to Measure the Electron Neutrino Mass with sub-eV sensitivity
- Exclusion limits on the WIMP-nucleon cross-section from the Cryogenic Dark Matter Search
- First Searches for Axions and Axion-Like Particles with the LUX Experiment
- Development of Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
- The projected background for the CUORE experiment
- DUNE as the Next-Generation Solar Neutrino Experiment
- A proposal to search for a monochromatic component of solar axions using Fe
- Limits on Axion Couplings from the first 80-day data of PandaX-II Experiment
- A Calorimetric Search on Double Beta Decay of 130Te
- Search for Axions with the CDMS Experiment
- Results of Dark Matter Search using the Full PandaX-II Exposure
- Axion Dark Matter Detection using Atomic Transitions
- Axion searches with the EDELWEISS-II experiment
- Particle Dark Matter and Solar Axion Searches with a small germanium detector at the Canfranc Underground Laboratory
- Production of high purity TeO2 single crystals for the study of neutrinoless double beta decay
- First Results of the EDELWEISS WIMP Search using a 320 g Heat-and-Ionization Ge Detector
- Phonon traps reduce the quasiparticle density in superconducting circuits
- New Limit for Neutrinoless Double-Beta Decay of Mo from the CUPID-Mo Experiment
- Final result of CUPID-0 phase-I in the search for the Se Neutrinoless Double Beta Decay
- Development of a Li2MoO4 scintillating bolometer for low background physics
- Search for Solar Axions Produced in Reaction with Borexino Detector
- Search for solar axions in XMASS, a large liquid-xenon detector
- Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
- CUORE-0 detector: design, construction and operation
- Validation of techniques to mitigate copper surface contamination in CUORE
- The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
- CUPID-0: the first array of enriched scintillating bolometers for 0νββdecay investigations
- CUORE crystal validation runs: results on radioactive contamination and extrapolation to CUORE background
- Characterization of bolometric Light Detectors for rare event searches
- Search for Solar Axions Using Fe-57
- Search for 14.4 keV solar axions emitted in the M1-transition of 57Fe nuclei with CAST
- Search for solar axions using Li-7
- Alive and well: a short review about standard solar models
- RES-NOVA: A new neutrino observatory based on archaeological lead
- An active noise cancellation technique for the CUORE Pulse Tube Cryocoolers
- Sensitivity of the spherical gravitational wave detector MiniGRAIL operating at 5 K
- Discovery of the Eu decay
- Measurement of the 2 Decay Half-life of Te with CUORE
- The Microcalorimeter Arrays for a Rhenium Experiment (MARE): a next-generation calorimetric neutrino mass experiment
- Search for Solar Axions Produced by Primakoff Conversion Using Resonant Absorption by Tm Nuclei
- Improved limits on solar axions and bosonic dark matter from the CDEX-1B experiment using the profile likelihood ratio method
- CUORE Sensitivity to Decay
- Radiopurity of an archeological Roman Lead cryogenic detector
- Theoretical Estimate of the Sensitivity of the CUORE Detector to Solar Axions
- A CsI low temperature detector for dark matter search
- The saga of neutrinoless double beta decay search with TeO2 thermal detectors
- How many sigmas is the solar neutrino effect?
- The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments
- Search for axioelectric effect of 5.5 MeV solar axions using BGO detectors
- Radon mitigation during the installation of the CUORE decay detector
- Search for Neutrinoless Decay of Te with CUORE-0
- Study of Supernova ν-Nucleus Coherent Scattering Interactions
- An innovative technique for the investigation of the 4-fold forbidden beta-decay of V
- A search for solar axion induced signals with COSINE-100
- Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE
- Search for axioelectric effect of solar axions using BGO scintillating bolometer
- Saving superconducting quantum processors from qubit decay and correlated errors generated by gamma and cosmic rays
- The Faraday room of the CUORE Experiment
- An assembly line for the construction of ultra-pure detectors
- Supernova Burst Observations with DUNE
- A CUPID LiMoO scintillating bolometer tested in the CROSS underground facility
- Characterization of cubic LiMoO crystals for the CUPID experiment
- Study of Rare Nuclear Processes with CUORE