An active noise cancellation technique for the CUORE Pulse Tube Cryocoolers
arXiv:1712.02753 · doi:10.1016/j.cryogenics.2018.05.001
Abstract
The Cryogenic Underground Observatory for Rare Events (CUORE) experiment at Gran Sasso National Laboratory of INFN searches for neutrinoless double beta decay using TeO2 crystals as cryogenic bolometers. The sensitivity of the measurement heavily depends on the energy resolution of the detector, therefore the success of the experiment stands on the capability to provide an extremely low noise environment. One of the most relevant sources of noise are the mechanical vibrations induced by the five Pulse Tube cryocoolers used on the cryogenic system which houses the detectors. To address this problem, we developed a system to control the relative phases of the pulse tube pressure oscillations, in order to achieve coherent superposition of the mechanical vibrations transmitted to the detectors. In the following, we describe this method and report on the results in applying it to the CUORE system.
arXiv comment11 pages, 11 figures
References in corpus (9)
- Planck 2015 results. XIII. Cosmological parameters
- First Results from CUORE: A Search for Lepton Number Violation via Decay of Te
- Searching for neutrinoless double-beta decay of Te with CUORE
- Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in Te with CUORE-0
- CUORE-0 detector: design, construction and operation
- Vibrations on pulse tube based Dry Dilution Refrigerators for low noise measurements
- The front-end electronics system for the CUORE experiment
- Two-stage high frequency pulse tube cooler for refrigeration at 25 K
- The CUORE cryostat
Cited by in corpus (19)
- First Results from CUORE: A Search for Lepton Number Violation via Decay of Te
- Improved Limit on Neutrinoless Double-Beta Decay in Te with CUORE
- The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
- Closed-cycle, low-vibration 4 K cryostat for ion traps and other applications
- An ultra-stable cryogenic sapphire cavity laser with an instability of based on a low vibration level cryostat
- CUPID, the CUORE Upgrade with Particle IDentification
- Final results of CALDER: Kinetic inductance light detectors to search for rare events
- New direct limit on neutrinoless double beta decay half-life of Te with CUORE
- The CUORE cryostat
- Characterization of two fast-turnaround dry dilution refrigerators for scanning probe microscopy
- A laser interferometer accelerometer for vibration sensitive cryogenic experiments
- An automated system to define the optimal operating settings of cryogenic calorimeters
- The environmental low-frequency background for macro-calorimeters at the millikelvin scale
- An analytical model for electronic noise in a cryogenic bolometer detector readout circuit
- CUORE Opens the Door to Tonne-scale Cryogenics Experiments
- Study of the effect of external noise pickups on the performance of a cryogenic bolometer
- The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment
- Cryogenic light detectors with thermal signal amplification for search experiments
- Search for Double-Beta Decay of to the States of with CUORE