Cryogenic light detectors with thermal signal amplification for search experiments
arXiv:2507.15732 · doi:10.1088/1748-0221/21/01/P01035
Abstract
As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of LiMoO crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of (10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.
arXiv commentPrepared for submission to JHEP; 33 pages, 13 figures, and 6 tables
References in corpus (33)
- Toward the discovery of matter creation with neutrinoless double-beta decay
- Scintillating double beta decay bolometers
- Development of Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
- First Results from the AMoRE-Pilot neutrinoless double beta decay experiment
- The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects
- Final result of CUPID-0 phase-I in the search for the Se Neutrinoless Double Beta Decay
- The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
- CUPID-0: the first array of enriched scintillating bolometers for 0νββdecay investigations
- Vibrations on pulse tube based Dry Dilution Refrigerators for low noise measurements
- Random coincidence of decay events as a background source in bolometric decay experiments
- An active noise cancellation technique for the CUORE Pulse Tube Cryocoolers
- Optimizing the energy threshold of light detectors coupled to luminescent bolometers
- The -decay CROSS experiment: preliminary results and prospects
- Rejection of randomly coinciding events in LiMoO scintillating bolometers using light detectors based on the Neganov-Luke effect
- Charge-to-heat transducers exploiting the Neganov-Trofimov-Luke effect for light detection in rare-event searches
- Improved limit on neutrinoless double beta decay of Mo from AMoRE-I
- Rejection of randomly coinciding events in ZnMoO scintillating bolometers
- Novel technique for the study of pile-up events in cryogenic bolometers
- CUPID, the CUORE Upgrade with Particle IDentification
- Probing Beyond the Standard Model Physics with Double-beta Decays
- Phonon and light read out of a LiMoO crystal with multiplexed kinetic inductance detectors
- High resolution digitization system for the CROSS experiment
- Test of CdWO and LiMoO scintillating bolometers in the CROSS underground facility with upgraded detector suspension
- High resolution filtering and digitization system for cryogenic bolometric detectors
- A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
- Twelve-crystal prototype of LiMoO scintillating bolometers for CUPID and CROSS experiments
- LiMoO Scintillating Bolometers for Rare-Event Search Experiments
- Signals induced by charge-trapping in EDELWEISS FID detectors: analytical modeling and applications
- A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment
- Improved Modelling of Detector Response Effects in Phonon-based Crystal Detectors used for Dark Matter Searches
- BINGO innovative assembly for background reduction in bolometric experiments
- First demonstration of a TES based cryogenic LiMoOdetector for neutrinoless double beta decay search
- Development of large-volume TeO bolometers for the CROSS decay search experiment