Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks
arXiv:1809.03362 · doi:10.1088/1681-7575/aae008
Abstract
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to for CSF1 and for CSF2 at high atom density. The systematic uncertainties of CSF1 and CSF2 are reduced to and , respectively. Both fountain clocks regularly calibrate the scale unit of International Atomic Time (TAI) and the local realization of Coordinated Universal Time, UTC(PTB), and serve as references to measure the frequencies of local and remote optical frequency standards.
arXiv comment33 pages, 7 figures
References in corpus (27)
- Search for New Physics with Atoms and Molecules
- Improved limit on a temporal variation of from comparisons of Yb and Cs atomic clocks
- Progress in Atomic Fountains at LNE-SYRTE
- High-accuracy optical clock based on the octupole transition in 171Yb+
- Searching for an oscillating massive scalar field as a dark matter candidate using atomic hyperfine frequency comparisons
- Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shifts
- Realization of a time-scale with an accurate optical lattice clock
- Controlling the cold collision shift in high precision atomic interferometry
- A generalized Ramsey excitation scheme with suppressed light shift
- Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
- First international comparison of fountain primary frequency standards via a long distance optical fiber link
- Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2
- Contributing to TAI with a Secondary Representation of the SI Second
- A Cs-Based Optical Frequency Measurement Using Cross-Linked Optical and Microwave Oscillators
- Scattering of Cold Atom Coherences by Hot Atoms: Frequency Shifts from Background Gas Collisions
- Evaluating and Minimizing Distributed Cavity Phase Errors in Atomic Clocks
- Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks
- Frequency shift of hyperfine transitions due to blackbody radiation
- Landau Level Collapse in Gated Graphene Structures
- Optical Stabilization of a Microwave Oscillator for Fountain Clock Interrogation
- Remote frequency measurement of the 1S0-3P1 transition in laser cooled Mg-24
- Phase Analysis for Frequency Standards in the Microwave and Optical Domains
- Feshbach resonances in Cesium at Ultra-low Static Magnetic Fields
- Atomic Clock Measurements of Quantum Scattering Phase Shifts Spanning Feshbach Resonances at Ultralow Fields
- Comment on "first accuracy evaluation of NIST-F2"
- Atomic trajectory characterization in a fountain clock based on the spectrum of a hyperfine transition
- Loading of a fountain clock with an enhanced Low-Velocity Intense Source of atoms
Cited by in corpus (40)
- Improved limits for violations of local position invariance from atomic clock comparisons
- Coherent Optical Clock Down-Conversion for Microwave Frequencies with 10-18 Instability
- Roadmap towards the redefinition of the second
- Entanglement-enhanced quantum metrology: from standard quantum limit to Heisenberg limit
- Demonstration of a time scale based on a stable optical carrier
- SpaceQ -- Direct Detection of Ultralight Dark Matter with Space Quantum Sensors
- Measuring the stability of fundamental constants with a network of clocks
- Long term measurement of the Sr clock frequency at the limit of primary Cs clocks
- Towards a Transportable Aluminium Ion Quantum Logic Optical Clock
- In-Yb Coulomb crystal clock with systematic uncertainty
- Fiber-optic joint time and frequency transfer with the same wavelength
- Direct comparisons of European primary and secondary frequency standards via satellite techniques
- Absolute frequency measurement of the 171Yb optical lattice clock at KRISS using TAI for over a year
- Demonstration of the nearly continuous operation of an Yb optical lattice clock for half a year
- Realization of phase locking in good-bad-cavity active optical clock
- Ab initio quantum theory of mass defect and time dilation in trapped-ion optical clocks
- Evaluation of the systematic shifts of a optical clock
- Coherent excitation of the highly forbidden electric octupole transition in Yb
- Dual-comb-enhanced microwave clock synchronization over commercial fiber
- Improved Frequency Ratio Measurement with 87Sr and 171Yb Optical Lattice Clocks at NMIJ
- Observing spin-squeezed states under spin-exchange collisions for a second
- Absolute frequency measurement of a Yb optical clock at the limit of the Cs fountain
- A Review of Contemporary Atomic Frequency Standards
- A grating-chip atomic fountain
- Roles of electron correlation effects for accurate determination of factors of low-lying states of Cd and their applications to atomic clock
- Probing Bosonic Stars with Atomic Clocks
- Absolute frequency measurements with a robust, transportable ^{40}Ca^{+} optical clock
- Using atomic clocks to detect local dark matter halos
- Power-to-Frequency Conversion in Cryogenic Sapphire Resonators
- Evaluation of the relativistic redshift in frequency standards at KRISS
- Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI Limit
- Continuous optical generation of microwave signals for fountain clocks
- QSNET, a network of clocks for measuring the stability of fundamental constants
- Quantum Sensing Using Atomic Clocks for Nuclear and Particle Physics
- Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map
- Improved absolute frequency measurement of Yb at NMIJ with uncertainty below
- Absolute frequency measurement of a Lu optical frequency standard via link to international atomic time
- High-precision Time-Frequency Signal Simultaneous Transfer System via a WDM-based Fiber Link
- Development of a Cesium Fountain Clock at HUST: Preliminary Results
- The QTF-Backbone: Proposal for a Nationwide Optical Fibre Backbone in Germany for Quantum Technology and Time and Frequency Metrology