Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2
arXiv:1110.2590 · doi:10.1088/0026-1394/49/1/012
Abstract
We evaluate the frequency error from distributed cavity phase in the caesium fountain clock PTB-CSF2 at the Physikalisch-Technische Bundesanstalt with a combination of frequency measurements and ab initio calculations. The associated uncertainty is 1.3E-16, with a frequency bias of 0.4E-16. The agreement between the measurements and calculations explains the previously observed frequency shifts at elevated microwave amplitude. We also evaluate the frequency bias and uncertainty due to the microwave lensing of the atomic wavepackets. We report a total PTB-CSF2 systematic uncertainty of 4.1E-16.
arXiv comment15 pages, 5 figures, to be published in Metrologia
References in corpus (4)
- Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shifts
- Controlling the cold collision shift in high precision atomic interferometry
- Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks
- Evaluating and Minimizing Distributed Cavity Phase Errors in Atomic Clocks
Cited by in corpus (19)
- Progress in Atomic Fountains at LNE-SYRTE
- A strontium lattice clock with inaccuracy and its frequency
- Simultaneous remote transfer of accurate timing and optical frequency over a public fiber network
- Ultra-stable long distance optical frequency distribution using the Internet fiber network
- Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks
- Realization of a time-scale with an accurate optical lattice clock
- First international comparison of fountain primary frequency standards via a long distance optical fiber link
- Contributing to TAI with a Secondary Representation of the SI Second
- A Cs-Based Optical Frequency Measurement Using Cross-Linked Optical and Microwave Oscillators
- Atomic fountains and optical clocks at SYRTE: status and perspectives
- Least-squares analysis of clock frequency comparison data to deduce optimized frequency and frequency ratio values
- Optical Stabilization of a Microwave Oscillator for Fountain Clock Interrogation
- Effect of soil temperature on one-way optical frequency transfer through dense-wavelength-division-multiplexing fibre links
- Space-Time Reference with an Optical Link
- Phase Analysis for Frequency Standards in the Microwave and Optical Domains
- Iterative Precision Measurement of Branching Ratios Applied to 5P states in 88Sr+
- Entanglement-enhanced test proposal for local Lorentz-symmetry violation via spinor atoms
- Loading of a fountain clock with an enhanced Low-Velocity Intense Source of atoms
- Comment on "first accuracy evaluation of NIST-F2"