Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shifts
arXiv:1107.2412 · doi:10.1088/0026-1394/48/5/007
Abstract
We evaluate the distributed cavity phase and microwave lensing frequency shifts, which were the two largest sources of uncertainty for the NPL-CsF2 cesium fountain clock. We report measurements that confirm a detailed theoretical model of the microwave cavity fields and the frequency shifts of the clock that they produce. The model and measurements significantly reduce the distributed cavity phase uncertainty to . We derive the microwave lensing frequency shift for a cylindrical cavity with circular apertures. An analytic result with reasonable approximations is given, in addition to a full calculation that indicates a shift of . The measurements and theoretical models we report, along with improved evaluations of collisional and microwave leakage induced frequency shifts, reduce the frequency uncertainty of the NPL-CsF2 standard to , nearly a factor of two lower than its most recent complete evaluation.
References in corpus (2)
Cited by in corpus (30)
- Frequency ratio of two optical clock transitions in Yb and constraints on the time-variation of fundamental constants
- Progress in Atomic Fountains at LNE-SYRTE
- A strontium lattice clock with inaccuracy and its frequency
- Ultra-stable long distance optical frequency distribution using the Internet fiber network
- Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks
- Improved tests of Local Position Invariance using 87Rb and 133Cs fountains
- Roadmap towards the redefinition of the second
- Autonomous quantum clocks: does thermodynamics limit our ability to measure time?
- Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2
- Contributing to TAI with a Secondary Representation of the SI Second
- A Cs-Based Optical Frequency Measurement Using Cross-Linked Optical and Microwave Oscillators
- Scattering of Cold Atom Coherences by Hot Atoms: Frequency Shifts from Background Gas Collisions
- Atomic fountains and optical clocks at SYRTE: status and perspectives
- A strontium optical lattice clock with uncertainty and measurement of its absolute frequency
- The unit of time: present and future directions
- Absolute frequency measurement of the 171Yb optical lattice clock at KRISS using TAI for over a year
- Realization of phase locking in good-bad-cavity active optical clock
- Systematic uncertainty due to background-gas collisions in trapped-ion optical clocks
- Machian Time Is To Be Abstracted From What Change?
- S-Wave Collisional Frequency Shift of a Fermion Clock
- Phase Analysis for Frequency Standards in the Microwave and Optical Domains
- Absolute frequency measurement of a Yb optical clock at the limit of the Cs fountain
- Frequency shifts in NIST Cs Primary Frequency Standards due To Transverse RF Field Gradients
- Hyperfine-induced quadrupole moments of alkali-metal atom ground states and their implications for atomic clocks
- Comment on "first accuracy evaluation of NIST-F2"
- Absolute frequencies of H13C14N hydrogen cyanide transitions in 1,5 μm region with saturated spectroscopy and sub-kHz scanning laser
- Improved absolute frequency measurement of Yb at NMIJ with uncertainty below
- Phase-shift in vapor cell and compact cold-atom frequency standards
- Drift-compensated Low-noise Frequency Synthesis Based on a cryoCSO for the KRISS-F1
- Development of NPL Rb fountain frequency standard