Improved absolute frequency measurement of Yb at NMIJ with uncertainty below
arXiv:2502.18914 · doi:10.1088/1681-7575/adb754
Abstract
We report improved absolute frequency measurement of the SP transition of Yb at National Metrology Institute of Japan (NMIJ) by comparing the Yb optical lattice clock NMIJ-Yb1 with 13 Cs primary frequency standards via International Atomic Time from August 2021 to May 2023. The measured absolute frequency is 518 295 836 590 863.62(10) Hz with a fractional uncertainty of , in good agreement with the recommended frequency of Yb as a secondary representation of the second. This uncertainty is 2.6 times lower than our previous measurement uncertainty, and slightly lower than any uncertainties of the absolute frequency measurements of Yb that have so far been reported by other institutes. We also estimate correlation coefficients between our present and previous measurements, which is important for updating the recommended frequency.
References in corpus (21)
- An Al quantum-logic clock with systematic uncertainty below
- Progress in Atomic Fountains at LNE-SYRTE
- Real-time geopotentiometry with synchronously linked optical lattice clocks
- A clock with systematic uncertainty
- Roadmap towards the redefinition of the second
- Improved limits on the coupling of ultralight bosonic dark matter to photons from optical atomic clock comparisons
- One-Dimensional Optical Lattice Clock with a Fermionic 171Yb Isotope
- Search for ultralight dark matter from long-term frequency comparisons of optical and microwave atomic clocks
- Long term measurement of the Sr clock frequency at the limit of primary Cs clocks
- Absolute frequency measurement of the 1S0 - 3P0 transition of 171Yb
- On a definition of the SI second with a set of optical clock transitions
- Absolute frequency measurement of the 171Yb optical lattice clock at KRISS using TAI for over a year
- Demonstration of the nearly continuous operation of an Yb optical lattice clock for half a year
- Yb optical clock with systematic uncertainty and absolute frequency measurements
- Absolute frequency measurement with uncertainty below using International Atomic Time
- Long-distance chronometric leveling with a portable optical clock
- Uncertainty evaluation of an Yb optical lattice clock at NMIJ
- Improved Frequency Ratio Measurement with 87Sr and 171Yb Optical Lattice Clocks at NMIJ
- Absolute frequency measurement of a Yb optical clock at the limit of the Cs fountain
- Generation of a precise time scale assisted by a near-continuously operating optical lattice clock
- Probe field ellipticity-induced shift in an atomic clock