Abstract
We report on a series of 42 measurements of the transition frequency of the 429~THz (5s)~S--(5s5p)~P line in Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement run has been extended by use of a hydrogen maser as flywheel to improve the statistical uncertainty given by the Cs clocks. We determine an averaged transition frequency of ~Hz with fractional uncertainty, at the limit of the current realization of the unit hertz. Analysis of the data provides an improved limit on the coupling of the gravitational potential of the Sun to the proton--electron mass ratio , and confirms the limits on its temporal drift.
arXiv comment8 pages, 4 figures
References in corpus (41)
- 1.5 m lasers with sub 10 mHz linewidth
- Optical clock intercomparison with precision in one hour
- Frequency ratio of two optical clock transitions in Yb and constraints on the time-variation of fundamental constants
- Improved limit on a temporal variation of from comparisons of Yb and Cs atomic clocks
- New Limits on Coupling of Fundamental Constants to Gravity Using Sr Optical Lattice Clocks
- 8E-17 fractional laser frequency instability with a long room-temperature cavity
- Experimenting an optical second with strontium lattice clocks
- Enhanced sensitivity to variation of the fine structure constant and m_p/m_e in diatomic molecules
- Sr lattice clock with inaccuracy below 10
- Systematic study of the Sr clock transition in an optical lattice
- A strontium lattice clock with inaccuracy and its frequency
- Dependence of nuclear magnetic moments on quark masses and limits on temporal variation of fundamental constants from atomic clock experiments
- The absolute frequency of the 87Sr optical clock transition
- Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks
- Realization of a time-scale with an accurate optical lattice clock
- Improved tests of Local Position Invariance using 87Rb and 133Cs fountains
- An accurate optical lattice clock with 87Sr atoms
- Improved frequency measurement of a one-dimensional optical lattice clock with a spin-polarized fermionic Sr isotope
- The 87-Sr optical frequency standard at PTB
- Measuring the frequency of a Sr optical lattice clock using a 120-km coherent optical transfer
- An Optical Lattice Clock with Spin-polarized 87Sr Atoms
- Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
- Noise and instability of an optical lattice clock
- Direct comparison of a Ca+ single ion clock against a Sr optical lattice clock
- Strategies for reducing the light shift in atomic clocks
- On the relation between uncertainties of weighted frequency averages and the various types of Allan deviations
- Tests of local position invariance using continuously running atomic clocks
- Variation of fundamental constants: theory and observations
- Measurement of the variation of electron-to-proton mass ratio using ultracold molecules produced from laser-cooled atoms
- Search for a drifting proton--electron mass ratio from H
- Providing 1E-16 short-term stability of a 1.5 μm laser to optical clocks
- Stability Transfer between Two Clock Lasers Operating at Different Wavelengths for Absolute Frequency Measurement of Clock Transition in 87Sr
- End-to-end topology for fiber comb based optical frequency transfer at the level
- SI-traceable measurement of an optical frequency at low level without a local primary standard
- Spectroscopy and frequency measurement of the Sr clock transition by laser linewidth transfer using an optical frequency comb
- The unit of time: present and future directions
- The sensitivity of hyperfine structure to nuclear radius and quark mass variation
- Absolute frequency measurement with uncertainty below using International Atomic Time
- Improved frequency measurement of the - clock transition in Sr using the Cs fountain clock at NMIJ as a transfer oscillator
- Limits on gravitational Einstein Equivalence Principle violation from monitoring atomic clock frequencies during a year
- Search for varying constants of nature from astronomical observation of molecules
Cited by in corpus (25)
- Improved limits for violations of local position invariance from atomic clock comparisons
- Roadmap towards the redefinition of the second
- Improved limits on the coupling of ultralight bosonic dark matter to photons from optical atomic clock comparisons
- Laser cooled molecules
- Search for ultralight dark matter from long-term frequency comparisons of optical and microwave atomic clocks
- Evaluation of lattice light shift at low 10 uncertainty for a shallow lattice Sr optical clock
- Optical frequency ratio of a single-ion clock and a lattice clock
- A transportable clock laser system with an instability of
- In-Yb Coulomb crystal clock with systematic uncertainty
- Long-distance chronometric leveling with a portable optical clock
- Absolute frequency of at uncertainty by reference to remote Primary Frequency Standards
- Coherent excitation of the highly forbidden electric octupole transition in Yb
- Ultralight Dark Matter Search with Space-Time Separated Atomic Clocks and Cavities
- Absolute frequency measurement of the 87Sr optical lattice clock at NTSC using International Atomic Time
- Absolute frequency measurement of a Yb optical clock at the limit of the Cs fountain
- Optically loaded Strontium lattice clock with a single multi-wavelength reference cavity
- Evaluation of the blackbody radiation shift of an Yb optical lattice clock at KRISS
- Absolute frequency measurements with a robust, transportable ^{40}Ca^{+} optical clock
- Constraints on violation of Lorentz symmetry with clock-comparison redshift experiments
- Continuous optical generation of microwave signals for fountain clocks
- Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map
- Improved absolute frequency measurement of Yb at NMIJ with uncertainty below
- High-accuracy multi-ion spectroscopy with mixed-species Coulomb crystals
- Varying fundamental constants cosmography
- The QTF-Backbone: Proposal for a Nationwide Optical Fibre Backbone in Germany for Quantum Technology and Time and Frequency Metrology