Absolute frequency of at uncertainty by reference to remote Primary Frequency Standards
arXiv:2008.00723 · doi:10.1088/1681-7575/abc232
Abstract
The optical lattice clock NICT-Sr1 regularly reports calibration measurements of the international timescale TAI. By comparing measurement results to the reports of eight Primary Frequency Standards, we find the absolute frequency of the clock transition to be f(Sr)=, with a fractional uncertainty of less than 1.8x10 approaching the systematic limits of the best realization of SI second. Our result is consistent with other recent measurements and further supported by the loop closure over the absolute frequencies of , and direct optical measurements of their ratio.
arXiv comment18 pages, 5 figures, 5 tables
References in corpus (18)
- Systematic evaluation of an atomic clock at 2e-18 total uncertainty
- Atomic clock performance beyond the geodetic limit
- An Al quantum-logic clock with systematic uncertainty below
- Optical clock comparison test of Lorentz symmetry
- Frequency ratio of Yb and Sr clocks with uncertainty at 150 s averaging time
- First observation with global network of optical atomic clocks aimed for a dark matter detection
- Realization of a time-scale with an accurate optical lattice clock
- Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
- Contributing to TAI with a Secondary Representation of the SI Second
- Long term measurement of the Sr clock frequency at the limit of primary Cs clocks
- SI-traceable measurement of an optical frequency at low level without a local primary standard
- A strontium optical lattice clock with uncertainty and measurement of its absolute frequency
- Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
- Least-squares analysis of clock frequency comparison data to deduce optimized frequency and frequency ratio values
- Absolute frequency measurement of the SF optical clock transition in Yb with an uncertainty of using a frequency link to International Atomic Time
- Absolute frequency measurement with uncertainty below using International Atomic Time
- Improved frequency measurement of the - clock transition in Sr using the Cs fountain clock at NMIJ as a transfer oscillator
- Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks
Cited by in corpus (12)
- Roadmap towards the redefinition of the second
- An Optical Atomic Clock Based on a Highly Charged Ion
- Optical frequency ratio of a single-ion clock and a lattice clock
- Absolute frequency measurement of the 171Yb optical lattice clock at KRISS using TAI for over a year
- Frequency ratio of an In ion clock and a Sr optical lattice clock
- Absolute frequency measurement of a Yb optical clock at the limit of the Cs fountain
- Atomic clocks highly sensitive to the variation of the fine structure constant based on Hf II, Hf IV, and W VI ions
- Absolute frequency measurements with a robust, transportable ^{40}Ca^{+} optical clock
- Continuous optical generation of microwave signals for fountain clocks
- Improved absolute frequency measurement of Yb at NMIJ with uncertainty below
- Absolute frequency measurement of a Lu optical frequency standard via link to international atomic time
- A High-frequency Geodetic VLBI Experiment for Optical Clock Comparison