Absolute frequency measurement with uncertainty below using International Atomic Time
arXiv:1611.08668 · doi:10.1007/s00340-016-6603-9
Abstract
The absolute frequency of the clock transition measured in 2015 was reevaluated using an improved frequency link to the SI second. The scale interval of International Atomic Time (TAI) that we used as the reference was calibrated for an evaluation interval of five days instead of the conventional interval of one month which is regularly employed in Circular T. The calibration on a five-day basis removed the uncertainty in assimilating the TAI scale of the five-day mean to that of the one-month mean. The reevaluation resulted in the total uncertainty of level for the first time without local cesium fountains. Since there are presumably no correlations among systematic shifts of cesium fountains worldwide, the measurement is not limited by the systematic uncertainty of a specific primary frequency standard.
arXiv commentApplied Physics B, in press
References in corpus (11)
- Frequency Comparison of Two High-Accuracy Al+ Optical Clocks
- Systematic evaluation of an atomic clock at 2e-18 total uncertainty
- Single-Ion Atomic Clock with Systematic Uncertainty
- Experimenting an optical second with strontium lattice clocks
- A strontium lattice clock with inaccuracy and its frequency
- Realization of a time-scale with an accurate optical lattice clock
- Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
- Stability Transfer between Two Clock Lasers Operating at Different Wavelengths for Absolute Frequency Measurement of Clock Transition in 87Sr
- Spectroscopy and frequency measurement of the Sr clock transition by laser linewidth transfer using an optical frequency comb
- Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
- Improved frequency measurement of the - clock transition in Sr using the Cs fountain clock at NMIJ as a transfer oscillator
Cited by in corpus (14)
- Geodesy and metrology with a transportable optical clock
- Long term measurement of the Sr clock frequency at the limit of primary Cs clocks
- SI-traceable measurement of an optical frequency at low level without a local primary standard
- A strontium optical lattice clock with uncertainty and measurement of its absolute frequency
- Demonstration of the nearly continuous operation of an Yb optical lattice clock for half a year
- Absolute frequency measurement of the SF optical clock transition in Yb with an uncertainty of using a frequency link to International Atomic Time
- Precision measurements on the Ba clock transition
- Absolute frequency of at uncertainty by reference to remote Primary Frequency Standards
- Frequency measurement of the clock transition of an indium ion sympathetically-cooled in a linear trap
- Intercombination line frequencies in Yb validated with the clock transition
- Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI Limit
- Months-long real-time generation of a time scale based on an optical clock
- Improved absolute frequency measurement of Yb at NMIJ with uncertainty below
- Absolute frequency measurement of a Lu optical frequency standard via link to international atomic time