Improved Frequency Ratio Measurement with 87Sr and 171Yb Optical Lattice Clocks at NMIJ
arXiv:2010.09976 · doi:10.1088/1681-7575/abc104
Abstract
We report improved frequency ratio measurement with Sr and Yb optical lattice clocks at the National Metrology Institute of Japan (NMIJ). The Sr optical lattice clock is enhanced with several major modifications and is re-evaluated with a reduced uncertainty of . We employed a Yb optical lattice clock with an uncertainty of that was developed for contributing to International Atomic Time (TAI). The measurement result is = 1.207 507 039 343 338 58(49)(6) with a fractional uncertainty of , which is 3.4 times smaller than our previous measurement result.
arXiv comment8 pages, 6 figures, 1 table
References in corpus (24)
- An Optical Lattice Clock with Accuracy and Stability at the Level
- Frequency Comparison of Two High-Accuracy Al+ Optical Clocks
- Systematic evaluation of an atomic clock at 2e-18 total uncertainty
- Atomic clock performance beyond the geodetic limit
- An Al quantum-logic clock with systematic uncertainty below
- Single-Ion Atomic Clock with Systematic Uncertainty
- Geodesy and metrology with a transportable optical clock
- A clock network for geodesy and fundamental science
- JILA SrI Optical Lattice Clock with Uncertainty of
- Progress in Atomic Fountains at LNE-SYRTE
- A transportable optical lattice clock with uncertainty
- Frequency ratio of Yb and Sr clocks with uncertainty at 150 s averaging time
- High accuracy correction of blackbody radiation shift in an optical lattice clock
- Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks
- Probing Interactions between Ultracold Fermions
- Operational Magic Intensity for Sr Optical Lattice Clocks
- Frequency ratios of Sr, Yb and Hg based optical lattice clocks and their applications
- Spectroscopy and frequency measurement of the Sr clock transition by laser linewidth transfer using an optical frequency comb
- Frequency ratio measurement of 171Yb and 87Sr optical lattice clocks
- Least-squares analysis of clock frequency comparison data to deduce optimized frequency and frequency ratio values
- Demonstration of the nearly continuous operation of an Yb optical lattice clock for half a year
- Improved frequency measurement of the - clock transition in Sr using the Cs fountain clock at NMIJ as a transfer oscillator
- Uncertainty evaluation of an Yb optical lattice clock at NMIJ
- Dual-Mode Operation of an Optical Lattice Clock Using Strontium and Ytterbium Atoms
Cited by in corpus (4)
- Absolute frequency measurement of the 171Yb optical lattice clock at KRISS using TAI for over a year
- Generation of a precise time scale assisted by a near-continuously operating optical lattice clock
- Accurate Determination of Blackbody Radiation Shifts in a Strontium Molecular Lattice Clock
- Improved absolute frequency measurement of Yb at NMIJ with uncertainty below