Performance of a continuously rotating half-wave plate on the POLARBEAR telescope
arXiv:1702.07111 · doi:10.1088/1475-7516/2017/05/008
Abstract
A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, , and , thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector pairs. We focus on the implementation of CRHWPs in large aperture telescopes (i.e. the primary mirror is larger than the current maximum half-wave plate diameter of 0.5 m), where the CRHWP can be placed between the primary mirror and focal plane. In this configuration, one needs to address the intensity to polarization () leakage of the optics, which becomes a source of 1/f noise and also causes differential gain systematics that arise from CMB temperature fluctuations. In this paper, we present the performance of a CRHWP installed in the POLARBEAR experiment, which employs a Gregorian telescope with a 2.5 m primary illumination pattern. The CRHWP is placed near the prime focus between the primary and secondary mirrors. We find that the leakage is larger than the expectation from the physical properties of our primary mirror, resulting in a 1/f knee of 100 mHz. The excess leakage could be due to imperfections in the detector system, i.e. detector non-linearity in the responsivity and time-constant. We demonstrate, however, that by subtracting the leakage correlated with the intensity signal, the 1/f noise knee frequency is reduced to 32 mHz (39 for our scan strategy), which is very promising to probe the primordial B-mode signal. We also discuss methods for further noise subtraction in future projects where the precise temperature control of instrumental components and the leakage reduction will play a key role.
27 pages, 5 figures, 3 tables, published version in JCAP. Includes some minor corrections
References in corpus (6)
- CMB Polarization Systematics Due to Beam Asymmetry: Impact on Inflationary Science
- Systematic errors in cosmic microwave background polarization measurements
- Improved Performance of TES Bolometers using Digital Feedback
- Design and development of an ambient-temperature continuously-rotating achromatic half-wave plate for CMB polarization modulation on the POLARBEAR-2 experiment
- SPIDER: A Balloon-borne Large-scale CMB Polarimeter
- Development of large radii half-wave plates for CMB satellite missions
Cited by in corpus (39)
- The Simons Observatory: Science goals and forecasts
- A Measurement of the Cosmic Microwave Background -Mode Polarization Power Spectrum at Sub-Degree Scales from 2 years of POLARBEAR Data
- A Measurement of the Degree Scale CMB B-mode Angular Power Spectrum with POLARBEAR
- Results from the Atacama B-mode Search (ABS) Experiment
- The Simons Observatory: gain, bandpass and polarization-angle calibration requirements for B-mode searches
- A measurement of the CMB E-mode angular power spectrum at subdegree scales from 670 square degrees of POLARBEAR data
- Impact of Polarized Galactic Foreground Emission on CMB Lensing Reconstruction and Delensing of B-Modes
- A Large-Diameter Hollow-Shaft Cryogenic Motor Based on a Superconducting Magnetic Bearing for Millimeter-Wave Polarimetry
- Likelihood methods for CMB experiments
- Improved upper limit on degree-scale CMB B-mode polarization power from the 670 square-degree POLARBEAR survey
- Small Aperture Telescopes for the Simons Observatory
- The EBEX Balloon Borne Experiment - Detectors and Readout
- A cryogenic continuously rotating half-wave plate for the POLARBEAR-2b cosmic microwave background receiver
- Framework for analysis of next generation, polarised CMB data sets in the presence of galactic foregrounds and systematic effects
- The Atacama Cosmology Telescope: Map-Based Noise Simulations for DR6
- Two Year Cosmology Large Angular Scale Surveyor (CLASS) Observations: Long Timescale Stability Achieved with a Front-End Variable-delay Polarization Modulator at 40 GHz
- Measurements of tropospheric ice clouds with a ground-based CMB polarization experiment, POLARBEAR
- Studies of Systematic Uncertainties for Simons Observatory: Detector Array Effects
- Impact of half-wave plate systematics on the measurement of cosmic birefringence from CMB polarization
- A large-diameter cryogenic rotation stage for half-wave plate polarization modulation on the POLARBEAR-2 experiment
- The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes
- Requirements for future CMB satellite missions: photometric and band-pass response calibration
- QUBIC VI: cryogenic half wave plate rotator, design and performances
- Precipitable water vapour measurement using GNSS data in the Atacama Desert for millimetre and submillimetre astronomical observations
- Systematic effects induced by Half Wave Plate precession into Cosmic Microwave Background polarization measurements
- Exploration of the polarization angle variability of the Crab Nebula with POLARBEAR and its application to the search for axion-like particles
- The Simons Observatory: Development and Optical Evaluation of Achromatic Half-Wave Plates
- Impact of half-wave plate systematics on the measurement of CMB -mode polarization
- Intensity-Coupled-Polarization in Instruments with a Continuously Rotating Half-Wave Plate
- MAPPRAISER: A massively parallel map-making framework for multi-kilo pixel CMB experiments
- Modelling TES non-linearity induced by a rotating HWP in a CMB polarimeter
- Multi-dimensional optimisation of the scanning strategy for the LiteBIRD space mission
- Anti-reflection coating with mullite and Duroid for large-diameter cryogenic sapphire and alumina optics
- The Simons Observatory: Validation of reconstructed power spectra from simulated filtered maps for the Small Aperture Telescope survey
- Characterization of a half-wave plate for cosmic microwave background circular polarization measurement with POLARBEAR
- A measurement of atmospheric circular polarization with POLARBEAR
- Mitigating point-source contamination in CMB polarization: a Generalized Point Spread Function fitting approach
- The Simons Observatory: Quantifying the impact of beam chromaticity on large-scale B-mode science
- Calibration of detector time constant with a thermal source for the POLARBEAR-2A CMB polarization experiment