Systematic effects induced by Half Wave Plate precession into Cosmic Microwave Background polarization measurements
arXiv:1906.07010 · doi:10.1051/0004-6361/201834495
Abstract
The most accessible method to measure polarization features of the CMB radiation is by means of a Stokes Polarimeter based on the rotation of an Half Wave Plate. The current observational cosmology is starting to be limited by the presence of systematic effects. The Stokes polarimeter with a rotating Half Wave Plate (HWP) has the advantage of mitigating a long list of potential systematics, by modulation of the linearly polarized component of the radiation, but the presence of the rotating HWP can by itself introduce new systematic effects, which must be under control, representing one of the most critical part in the design of a B-Modes experiment. In this paper we present, simulate and analyse the spurious signal arising from the precession of a rotating HWP. We first find an analytical formula for the impact of the systematic effect induced by the HWP precession on the propagating radiation, using the 3D generalization of the Muller formalism. We then perform several numerical simulations, showing the effect induced on the Stokes parameters by this systematic. We also derive and discuss the impact into B-modes measured by a satellite experiment. We find the analytical formula for the Stokes parameters from a Stokes polarimeter where the HWP follows a precessional motion with an angle . We show the result depending on the HWP inertia tensor, spinning speed and on . The result of numerical simulations is reported as a simple timeline of the electric fields. Finally, assuming to observe all the sky with a satellite mission, we analyze the effect on B-modes measurements. The effect is not negligible giving the current B-modes experiments sensitivity, therefore it is a systematic which needs to be carefully considered for future experiments.
arXiv comment18 pages
References in corpus (32)
- Planck 2015 results. XIII. Cosmological parameters
- HEALPix -- a Framework for High Resolution Discretization, and Fast Analysis of Data Distributed on the Sphere
- Planck 2018 results. I. Overview and the cosmological legacy of Planck
- BICEP2 I: Detection Of B-mode Polarization at Degree Angular Scales
- A Joint Analysis of BICEP2/Keck Array and Planck Data
- BICEP2 / Keck Array VI: Improved Constraints On Cosmology and Foregrounds When Adding 95 GHz Data From Keck Array
- The Microwave Anisotropy Probe (MAP) Mission
- Planck 2015 results. IX. Diffuse component separation: CMB maps
- The Atacama Cosmology Telescope: The polarization-sensitive ACTPol instrument
- How to make maps from CMB data without losing information
- The Scientific Programme of Planck
- Robust forecasts on fundamental physics from the foreground-obscured, gravitationally-lensed CMB polarization
- Systematic errors in cosmic microwave background polarization measurements
- Modulation of CMB polarization with a warm rapidly-rotating half-wave plate on the Atacama B-Mode Search (ABS) instrument
- Performance of a continuously rotating half-wave plate on the POLARBEAR telescope
- Systematic effects from an ambient-temperature, continuously-rotating half-wave plate
- Nonlinear Stokes Mueller Polarimetry
- Design and development of an ambient-temperature continuously-rotating achromatic half-wave plate for CMB polarization modulation on the POLARBEAR-2 experiment
- Modeling dielectric half-wave plates for cosmic microwave background polarimetry using a Mueller matrix formalism
- POLARBEAR-2: an instrument for CMB polarization measurements
- A Large-Diameter Hollow-Shaft Cryogenic Motor Based on a Superconducting Magnetic Bearing for Millimeter-Wave Polarimetry
- The EBEX Balloon Borne Experiment - Optics, Receiver, and Polarimetry
- A cryogenic rotation stage with a large clear aperture for the half-wave plates in the Spider instrument
- A cryogenic waveplate rotator for polarimetry at mm and sub-mm wavelengths
- Optimal scan strategies for future CMB satellite experiments
- A Translational Polarization Rotator
- Exploring cosmic origins with CORE: mitigation of systematic effects
- Modeling and characterization of the SPIDER half-wave plate
- The short wavelength instrument for the polarization explorer balloon-borne experiment: Polarization modulation issues
- Common-mode rejection in Martin-Puplett spectrometers for astronomical observations at mm-wavelengths
- QUBIC Technical Design Report
- Leakage of power from dipole to higher multipoles due to non-symmetric WMAP beam
Cited by in corpus (4)
- Instrumental systematics biases in CMB lensing reconstruction: a simulation-based assessment
- A numerical study of observational systematic errors in lensing analysis of CMB polarization
- QUBIC VI: cryogenic half wave plate rotator, design and performances
- Fast map-based simulations of systematics in CMB surveys including effects of the scanning strategy