On Pulsar Distance Measurements and their Uncertainties
arXiv:1206.0428 · doi:10.1088/0004-637X/755/1/39
Abstract
Accurate distances to pulsars can be used for a variety of studies of the Galaxy and its electron content. However, most distance measures to pulsars have been derived from the absorption (or lack thereof) of pulsar emission by Galactic HI gas, which typically implies that only upper or lower limits on the pulsar distance are available. We present a critical analysis of all measured HI distance limits to pulsars and other neutron stars, and translate these limits into actual distance estimates through a likelihood analysis that simultaneously corrects for statistical biases. We also apply this analysis to parallax measurements of pulsars in order to obtain accurate distance estimates and find that the parallax and HI distance measurements are biased in different ways, because of differences in the sampled populations. Parallax measurements typically underestimate a pulsar's distance because of the limited distance to which this technique works and the consequential strong effect of the Galactic pulsar distribution (i.e. the original Lutz-Kelker bias), in HI distance limits, however, the luminosity bias dominates the Lutz-Kelker effect, leading to overestimated distances because the bright pulsars on which this technique is applicable are more likely to be nearby given their brightness.
32 pages, 1 figure, 2 tables; Accepted for publication in the Astrophysical Journal
References in corpus (16)
- The ATNF Pulsar Catalogue
- Trigonometric Parallaxes of Massive Star Forming Regions: VI. Galactic Structure, Fundamental Parameters and Non-Circular Motions
- The Parkes multibeam pulsar survey: VI. Discovery and timing of 142 pulsars and a Galactic population analysis
- Pulsar Parallaxes at 5 GHz with the Very Long Baseline Array
- Extremely high precision VLBI astrometry of PSR J0437-4715 and implications for theories of gravity
- Isolated neutron stars: Magnetic fields, distances, and spectra
- The Distance of the SNR Kes 75 and PWN PSR J1846-0258 System
- The Distance and Age of the SNR Kes 73 and AXP 1E 1841-045
- Implications of a VLBI Distance to the Double Pulsar J0737-3039A/B
- The Distances of SNRs Kes 69 and G21.5-0.9 from HI and 13CO Spectra
- Discovery of Five Recycled Pulsars in a High Galactic Latitude Survey
- Distance Determination to the Crab-like PWN G54.1+0.3 and Search for its Supernova Remnant Shell
- The Parallax and Proper Motion of PSR J0030+0451
- Arecibo HI Absorption Measurements of Pulsars and the Electron Density at Intermediate Longitudes in the First Galactic Quadrant
- Neutral Hydrogen Absorption Toward XTE J1810-197: the Distance to a Radio-Emitting Magnetar
- Precision Southern Hemisphere pulsar VLBI astrometry: techniques and results for PSR J1559-4438