The single electron R-pump: first experiment
arXiv:cond-mat/0001206 · doi:10.1063/1.1347017
Abstract
We fabricated and tested the single electron R-pump, i.e. a three-junction Al circuit with on-chip Cr resistors. We show that due to the presence of the resistors (R > h/e^2 = 25.8 kOhm), the accuracy of electron transfer in the R-pump can approach the level of 10^-8. Preliminary results of experiment with the R-pump made at PTB are reported.
arXiv comment2 pages, incl. 3 figures
References in corpus (3)
Cited by in corpus (24)
- Single-electron current sources: towards a refined definition of ampere
- Gigahertz quantized charge pumping in graphene quantum dots
- Non-adiabadic charge pumping in a hybrid SET transistor
- Quantum Metrology Triangle Experiments: A Status Review
- Nanoampere pumping of Cooper pairs
- Evidence for universality of tunable-barrier electron pumps
- Electron Counting Capacitance Standard with an improved five-junction R-pump
- A hybrid metal/semiconductor electron pump for quantum metrology
- Properties of 1D two-barrier quantum pump with harmonically oscillating barriers
- Environmentally Activated Tunneling Events in a Hybrid Single-Electron Box
- Cooper pair cotunneling in single charge transistors with dissipative electromagnetic environment
- Pumping properties of the hybrid single-electron transistor in dissipative environment
- Measurement of coherent charge transfer in an adiabatic Cooper pair pump
- Andreev tunneling in charge pumping with SINIS turnstiles
- Waveform sampling using an adiabatically driven electron ratchet in a two-dimensional electron system
- Effect of Photon-Assisted Andreev Reflection in the Accuracy of a SINIS Turnstile
- Single-charge escape processes through a hybrid turnstile in a dissipative environment
- Coulomb blockade in two island systems with highly conductive junctions
- Electron counting capacitance standard and quantum metrology triangle experiments at PTB
- Ultra-high-ohmic microstripline resistors for Coulomb blockade devices
- Transport out of locally broken detailed balance
- Single-electron latch with granular film charge leakage suppressor
- Cotunneling mechanism of single-electron shuttling
- Steps towards a capacitance standard based on single-electron counting at PTB