First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection
arXiv:astro-ph/0701858 · doi:10.1016/j.astropartphys.2007.06.002
Abstract
Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ratio of these signals being different for the two classes of event. This ratio is calibrated for different incident species using an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days of running ZEPLIN-II, the total exposure following the application of fiducial and stability cuts was 225 kgxdays. A background population of radon progeny events was observed in this run, arising from radon emission in the gas purification getters, due to radon daughter ion decays on the surfaces of the walls of the chamber. An acceptance window, defined by the neutron calibration data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray and radon progeny induced background events. These figures provide a 90% c.l. upper limit to the number of nuclear recoils of 10.4 events in this acceptance window, which converts to a WIMP-nucleon spin-independent cross-section with a minimum of 6.6x10^-7 pb following the inclusion of an energy dependent, calibrated, efficiency. A second run is currently underway in which the radon progeny will be eliminated, thereby removing the background population, with a projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
38 Pages, 16 Figures, (v2: corrected table 2 description)
References in corpus (8)
- Correlated Fluctuations between Luminescence and Ionization in Liquid Xenon
- The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
- Neutron background in large-scale xenon detectors for dark matter searches
- Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils
- Measurements of Scintillation Efficiency and Pulse-Shape for Low Energy Recoils in Liquid Xenon
- Muon-induced neutron production and detection with GEANT4 and FLUKA
- Measurements of muon flux at 1070 metres vertical depth in the Boulby underground laboratory
- Scintillation efficiency of liquid xenon for nuclear recoils with the energy down to 5 keV
Cited by in corpus (102)
- A History of Dark Matter
- DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
- Hadronic Uncertainties in the Elastic Scattering of Supersymmetric Dark Matter
- The XENON100 Dark Matter Experiment
- Liquid Xenon Detectors for Particle Physics and Astrophysics
- Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
- The XENON1T Dark Matter Experiment
- Liquid noble gas detectors for low energy particle physics
- Scalar Multiplet Dark Matter
- Dark Matter Direct Detection with Non-Maxwellian Velocity Structure
- The impact of priors and observables on parameter inferences in the Constrained MSSM
- Inelastic Dark Matter in Light of DAMA/LIBRA
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- Characterising dark matter searches at colliders and direct detection experiments: Vector mediators
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Commissioning Run of the CRESST-II Dark Matter Search
- WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
- The Hunt for New Physics at the Large Hadron Collider
- Candidates for Inelastic Dark Matter
- Composite Inelastic Dark Matter
- Dark Matter Candidates - Axions, Neutralinos, Gravitinos, and Axinos
- Fitting the Phenomenological MSSM
- Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
- Design and Performance of the XENON10 Dark Matter Experiment
- Scintillation efficiency and ionization yield of liquid xenon for mono-energetic nuclear recoils down to 4 keV
- Supernova neutrino physics with xenon dark matter detectors: A timely perspective
- Dark Matter as the signal of Grand Unification
- New Measurement of the Scintillation Efficiency of Low-Energy Nuclear Recoils in Liquid Xenon
- Direct Detection of Dark Matter Debris Flows
- The Caustic Ring Model of the Milky Way Halo
- Observation of Anti-correlation between Scintillation and Ionization for MeV Gamma-Rays in Liquid Xenon
- Form Factor Dark Matter
- Distillation of Liquid Xenon to Remove Krypton
- New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV
- The XENONnT Dark Matter Experiment
- Nuclear recoil energy scale in liquid xenon with application to the direct detection of dark matter
- Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr
- Resonant Dark Matter
- Inelastic Dark Matter, Non-Standard Halos and the DAMA/LIBRA Results
- Dark Matter Capture in the First Stars: a Power Source and Limit on Stellar Mass
- Strategies for Determining the Nature of Dark Matter
- Light Higgses at the Tevatron and at the LHC and Observable Dark Matter in SUGRA and D Branes
- The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
- Annual Modulation in Direct Dark Matter Searches
- Measurement of single electron emission in two-phase xenon
- The ArDM Liquid Argon Time Projection Chamber at the Canfranc Underground Laboratory: a ton-scale detector for Dark Matter Searches
- Characterisation of a silicon photomultiplier device for applications in liquid argon based neutrino physics and dark matter searches
- Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
- Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
- A coherent understanding of low-energy nuclear recoils in liquid xenon
- Phenomenology of GUT-less Supersymmetry Breaking
- Reflectance of Polytetrafluoroethylene (PTFE) for Xenon Scintillation Light
- Low Background Gamma Spectroscopy at the Boulby Underground Laboratory
- A Dark Matter Model with Non-Abelian Gauge Symmetry
- Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon
- Direct Detection of Dark Matter -- APPEC Committee Report
- Measurements of neutrons produced by high-energy muons at the Boulby Underground Laboratory
- WIMP detection and slow ion dynamics in carbon nanotube arrays
- Limits on spin-dependent WIMP-nucleon cross-sections from the first ZEPLIN-II data
- Quenching Factor for Low Energy Nuclear Recoils in a Plastic Scintillator
- Parity Violation in Composite Inelastic Dark Matter Models
- Simulation of neutrons produced by high-energy muons underground
- Radioactivity Backgrounds in ZEPLIN-III
- Projected sensitivities of the LUX-ZEPLIN (LZ) experiment to new physics via low-energy electron recoils
- A Simple Explanation for DAMA with Moderate Channeling
- Operation of a Thick Gas Electron Multiplier (THGEM) in Ar, Xe and Ar-Xe
- Ab-initio electron scattering cross-sections and transport in liquid xenon
- Anisotropic diffusion of electrons in liquid xenon with application to improving the sensitivity of direct dark matter searches
- A Bayesian Analysis of the Constrained NMSSM
- Data Acquisition and Readout System for the LUX Dark Matter Experiment
- XAX: a multi-ton, multi-target detection system for dark matter, double beta decay and pp solar neutrinos
- The ZEPLIN-III Anti-Coincidence Veto Detector
- The Poker Face of Inelastic Dark Matter: Prospects at Upcoming Direct Detection Experiments
- Preparation of Neutron-activated Xenon for Liquid Xenon Detector Calibration
- Disentangling Dark Matter Dynamics with Directional Detection
- Performance of the veto detector incorporated into the ZEPLIN-III experiment
- Characterization of the QUartz Photon Intensifying Detector (QUPID) for Noble Liquid Detectors
- Panglossian Prospects for Detecting Neutralino Dark Matter in Light of Natural Priors
- Optical Readout of a Two Phase Liquid Argon TPC using CCD Camera and THGEMs
- Peaked Signals from Dark Matter Velocity Structures in Direct Detection Experiments
- The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- What it takes to measure a fundamental difference between dark matter and baryons: the halo velocity anisotropy
- Studies of a three-stage dark matter and neutrino observatory based on multi-ton combinations of liquid xenon and liquid argon detectors
- Scintillation and Ionization Responses of Liquid Xenon to Low Energy Electronic and Nuclear Recoils at Drift Fields from 236 V/cm to 3.93 kV/cm
- Discovery of underground argon with low level of radioactive 39Ar and possible applications to WIMP dark matter detectors
- Hierarchies of Susy Splittings and Invisible Photinos as Dark Matter
- Direct Detection of Cold Dark Matter
- Low-Energy (<10 keV) Electron Ionization and Recombination Model for a Liquid Argon Detector
- Dual-Phase Liquid Xenon Detectors for Dark Matter Searches
- High Resolution Gamma Ray Detection in a Dual Phase Xenon Time Projection Chamber
- Theoretical Interpretation of Experimental Data from Direct Dark Matter Detection
- The ZEPLIN II dark matter detector: data acquisition system and data reduction
- Neutrino masses, muon g-2, dark matter, lithium problem, and leptogenesis at TeV-scale
- A New Analysis Method for WIMP searches with Dual-Phase Liquid Xe TPCs
- Preliminary test results of LAr prototype detector
- Direct WIMP identification: Physics performance of a segmented noble-liquid target immersed in a Gd-doped water veto
- Performance data from the ZEPLIN-III second science run
- A CF3I-based SDD Prototype for Spin-independent Dark Matter Searches
- Heavy Scalar Dark Matter
- Physics at Underground Laboratories: Direct Detection of Dark Matter
- The Status of the Search for Low Mass WIMPs: 2013
- Recent results in the search for dark matter with noble liquid detectors