Material radioassay and selection for the XENON1T dark matter experiment
arXiv:1705.01828 · doi:10.1140/epjc/s10052-017-5329-0
Abstract
The XENON1T dark matter experiment aims to detect Weakly Interacting Massive Particles (WIMPs) through low-energy interactions with xenon atoms. To detect such a rare event necessitates the use of radiopure materials to minimize the number of background events within the expected WIMP signal region. In this paper we report the results of an extensive material radioassay campaign for the XENON1T experiment. Using gamma-ray spectroscopy and mass spectrometry techniques, systematic measurements of trace radioactive impurities in over one hundred samples within a wide range of materials were performed. The measured activities allowed for stringent selection and placement of materials during the detector construction phase and provided the input for XENON1T detection sensitivity estimates through Monte Carlo simulations.
References in corpus (16)
- Supersymmetric Dark Matter
- Big-Bang Nucleosynthesis
- A direct empirical proof of the existence of dark matter
- Dark Matter Results from 225 Live Days of XENON100 Data
- Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
- Muon `Depth -- Intensity' Relation Measured by LVD Underground Experiment and Cosmic-Ray Muon Spectrum at Sea Level
- Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
- Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment
- Removing krypton from xenon by cryogenic distillation to the ppq level
- Gator: a low-background counting facility at the Gran Sasso Underground Laboratory
- Analysis of the XENON100 Dark Matter Search Data
- Online Rn removal by cryogenic distillation in the XENON100 experiment
- Cosmogenic activation of xenon and copper
- Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
- A Database for Storing the Results of Material Radiopurity Measurements
- Radio-assay of Titanium samples for the LUX Experiment
Cited by in corpus (45)
- Dark Matter Search Results from a One TonneYear Exposure of XENON1T
- Excess Electronic Recoil Events in XENON1T
- The XENON1T Dark Matter Experiment
- Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- First observation of two-neutrino double electron capture in Xe with XENON1T
- The XENONnT Dark Matter Experiment
- Testing sterile neutrino mixing with present and future solar neutrino data
- Double-Weak Decays of Xe and Xe in the XENON1T and XENONnT Experiments
- Characterisation of Silicon Photomultipliers for Liquid Xenon Detectors
- Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment
- Rn emanation measurements for the XENON1T experiment
- Background assessment for the TREX Dark Matter experiment
- Search for inelastic scattering of WIMP dark matter in XENON1T
- Radiopurity assessment of the energy readout for the NEXT double beta decay experiment
- Disentangling the sources of ionizing radiation in superconducting qubits
- SAGE : A Monte Carlo Simulation Framework for Experiments with Germanium Detectors
- Magnetically-coupled piston pump for high-purity gas applications
- Cosmogenic activation in double beta decay experiments
- A new ultra low-level HPGe activity counting setup in the Felsenkeller shallow-underground laboratory
- Projected WIMP sensitivity of the CDEX-50 dark matter experiment
- GeMSE: a Low-Background Facility for Gamma-Spectrometry at Moderate Rock Overburden
- Measurement of ambient radon progeny decay rates and energy spectra in liquid argon using the MicroBooNE detector
- Simulation-based design study for the passive shielding of the COSINUS dark matter experiment
- Evaluation of radon adsorption efficiency values in xenon with activated carbon fibers
- The upgraded low-background germanium counting facility Gator for high-sensitivity -ray spectrometry
- Inelastic dark matter nucleus scattering
- Neutrinoless Double Beta Decay Sensitivity of the XLZD Rare Event Observatory
- QUEST-DMC: Background Modelling and Resulting Heat Deposit for a Superfluid Helium-3 Bolometer
- Abatement of Ionizing Radiation for Superconducting Quantum Devices
- CENS Experiment Proposal at CSNS
- Ultra-Low Background Germanium Assay at the Boulby Underground Laboratory
- XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference
- Assay of low-background stainless steel by smelting for the neutrino experiment at Jinping
- Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering
- Search for Pauli Exclusion Principle Violations with Gator at LNGS
- Initial performance of the high sensitivity alpha particle detector at the Yangyang underground laboratory
- Identification of radiopure tungsten for low background applications
- Mass spectrometric analyses of high performance polymers to assess radiopurity as ultra low background materials for rare event physics detectors
- Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of Xe
- AlphaCAMM, a Micromegas-based camera for high-sensitivity screening of alpha surface contamination
- An integrated online radioassay data storage and analytics tool for nEXO
- Monte Carlo Simulation Variance Reduction Techniques for Photon Transport in Liquid Xenon Detectors
- NaI(Tl) crystal scintillator encapsulated in two organic-scintillator layers with pulse shape data analysis
- Study on cosmogenic activation in copper for rare event search experiments