The upgraded low-background germanium counting facility Gator for high-sensitivity -ray spectrometry
arXiv:2204.12478 · doi:10.1088/1748-0221/17/08/P08010
Abstract
We describe the upgrade and performance of the high-purity germanium counting facility Gator, which is dedicated to low-background -ray spectrometry. Gator is operated at the Gran Sasso Underground Laboratory in Italy, at an average depth of 3600 meter water equivalent, and employed for material screening and selection in ultra-low background, rare-event search experiments in astroparticle physics. The detector is equipped with a passive shield made of layers of copper, lead and polyethylene, and the sample cavity is purged with gaseous nitrogen maintained at positive pressure for radon suppression. After upgrading its enclosure, the background rate is (82.00.7) counts/(kgday) in the energy region 100 keV to 2700 keV, a 20% reduction compared to the previously reported rate. We show the stability of various operation parameters as a function of time. We also summarize the sample analysis procedure, and demonstrate Gator's sensitivity by examining one material sample, a candidate photosensor for the DARWIN experiment.
References in corpus (3)
Cited by in corpus (5)
- The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- A new ultra low-level HPGe activity counting setup in the Felsenkeller shallow-underground laboratory
- First Sub-MeV Dark Matter Search with the QROCODILE Experiment Using Superconducting Nanowire Single-Photon Detectors
- Search for Pauli Exclusion Principle Violations with Gator at LNGS
- Development of a low-background HPGe detector at Kamioka Observatory