activity
20182026
most citedSearch for Neutrinoless Double-Beta Decay with the Complete EXO-200 Dataset

258 citations · 816 across the 34 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

21 papers · 1 filter

physics.ins-det2026

EXO-200 Public Data Release for AI/ML Applications

S. Al Kharusi, G. Anton, I. Badhrees +103

We present a public release of a subset of calibration data from the EXO-200 experiment, a liquid xenon time projection chamber designed to search for neutrinoless double-beta deca…

physics.ins-det2026

An optical cryostat for automated testing of silicon photomultipliers with vacuum-ultraviolet light

Lucas Darroch, Riya Rai, Soud Al Kharusi +8

We present the design and performance of an optical cryostat for testing silicon photomultipliers (SiPMs) with vacuum-ultraviolet (VUV) light. The cryostat operates within a temper…

physics.ins-det2026

The nEXO Radioassay Program

R. MacLellan, P. Acharya, B. Aharmim +148

Material radioactivity compilations, such as the one presented here, are important enablers of science. They are useful for the selection of radiopure materials used in the design…

physics.ins-det2026

Design of a high voltage delivery system for noble liquid time projection chambers

R. Saldanha, L. Pagani, E. Angelico +129

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dar…

physics.ins-det2025

Characterization of CRYO ASIC for charge readout in the nEXO experiment

Z. Li, M. Yu, E. Angelico +141

nEXO is a proposed next-generation experiment searching for the neutrinoless double beta decay of Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC). T…

physics.ins-det2025★ 3 cited

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

nEXO Collaboration, A. Anker, P. A. Breur +138

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a signif…

physics.ins-det2025

Measuring dark currents in multiple cryogenic SiPMs with sub-pA sensitivity using an automated IV multiplexer

Lucas Darroch, Eamon Egan, Marc-Antoine Leclerc +2

We present the design of an automated current-voltage (IV) multiplexer (MUX) that enables accurate measurement of the dark current in cryogenic silicon photomultipliers (SiPMs), ac…

physics.ins-det2023★ 2 cited

An integrated online radioassay data storage and analytics tool for nEXO

R. H. M. Tsang, A. Piepke, S. Al Kharusi +157

Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in…

physics.ins-det2022★ 26 cited

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

G. Gallina, Y. Guan, F. Retiere +162

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0), due to their response uniformity, monolithic sensitive volume,…

physics.ins-det2022★ 2 cited

Development of a Xe calibration source for nEXO

B. G. Lenardo, C. A. Hardy, R. H. M. Tsang +125

We study a possible calibration technique for the nEXO experiment using a Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($…

physics.ins-det2021★ 10 cited

The EXO-200 detector, part II: Auxiliary Systems

N. Ackerman, J. Albert, M. Auger +157

The EXO-200 experiment searched for neutrinoless double-beta decay of Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liqui…

physics.ins-det2021★ 12 cited

Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon

M. Wagenpfeil, T. Ziegler, J. Schneider +140

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work prese…

physics.ins-det2020★ 6 cited

Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage

T. Stiegler, S. Sangiorgio, J. P. Brodsky +148

nEXO is a proposed tonne-scale neutrinoless double beta decay () experiment using liquid (LXe) in a Time Projection Chamber (TPC) to read out ionization and scin…

physics.ins-det2019★ 18 cited

Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths

P. Lv, G. F. Cao, L. J. Wen +148

Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angula…

physics.ins-det2019★ 18 cited

Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode

O. Njoya, T. Tsang, M. Tarka +153

Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode…

physics.ins-det2019★ 17 cited

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon

P. Nakarmi, I. Ostrovskiy, A. K. Soma +152

Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next gen…

physics.ins-det2019★ 34 cited

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

200 Collaboration, G. Anton, I. Badhrees +99

Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and i…

physics.ins-det2019★ 15 cited

Simulation of charge readout with segmented tiles in nEXO

Z. Li, W. R. Cen, A. Robinson +150

nEXO is a proposed experiment to search for the neutrino-less double beta decay () of Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC wil…

physics.ins-det2018★ 11 cited

Study of Silicon Photomultiplier Performance in External Electric Fields

X. L. Sun, T. Tolba, G. F. Cao +149

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their per…

physics.ins-det2018★ 43 cited

VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO

A. Jamil, T. Ziegler, P. Hufschmidt +140

Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid al…

physics.ins-det2018★ 77 cited

nEXO Pre-Conceptual Design Report

nEXO Collaboration, S. Al Kharusi, A. Alamre +171

The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta () deca…