Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
arXiv:2209.07765 · doi:10.1140/epjc/s10052-022-11072-8
Abstract
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0 of \ce{^{136}Xe} with projected half-life sensitivity of ~yr. To reach this sensitivity, the design goal for nEXO is 1\% energy resolution at the decay -value (~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay -value for the nEXO design.
References in corpus (9)
- Characterization of the Hamamatsu VUV4 MPPCs for nEXO
- Measurement of the absolute reflectance of polytetrafluoroethylene (PTFE) immersed in liquid xenon
- Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
- Cryogenic SiPM arrays for the DUNE photon detection system
- SiPM cross-talk in liquid argon detectors
- Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
- Design and construction of Xenoscope -- a full-scale vertical demonstrator for the DARWIN observatory
- Scintillation detectors with silicon photomultiplier readout in a dilution refrigerator at temperatures down to 0.2 K
- Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
Cited by in corpus (11)
- The science and technology of liquid argon detectors
- Why would you put a flashlight in a dark matter detector?
- Front-end Electronics and Optimal Ganging Schemes for Single Photon Detection with Large Arrays of SiPMs in Liquid Argon
- Impact of extreme ultraviolet radiation on the scintillation of pure and xenon-doped liquid argon
- Supernova electron-neutrino interactions with xenon in the nEXO detector
- Measurements of the Quantum Yield of Silicon using Geiger-mode Avalanching Photodetectors
- Characterization of external cross-talk from silicon photomultipliers in a liquid xenon detector
- Canadian Contributions to the Search for Neutrinoless Double Beta Decay
- Measuring dark currents in multiple cryogenic SiPMs with sub-pA sensitivity using an automated IV multiplexer
- Xenon Signal Denoising via Supervised, Semi-Supervised, and Unsupervised Models
- Simulation Study of Photon-to-Digital Converter (PDC) Timing Specifications for LoLX Experiment