Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
arXiv:2209.07765 · doi:10.1140/epjc/s10052-022-11072-8
Abstract
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0 of \ce{^{136}Xe} with projected half-life sensitivity of ~yr. To reach this sensitivity, the design goal for nEXO is 1\% energy resolution at the decay -value (~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay -value for the nEXO design.
References in corpus (26)
- DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
- Liquid Xenon Detectors for Particle Physics and Astrophysics
- NEST: A Comprehensive Model for Scintillation Yield in Liquid Xenon
- Correlated Fluctuations between Luminescence and Ionization in Liquid Xenon
- Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
- nEXO Pre-Conceptual Design Report
- Cryogenic Characterization of FBK HD Near-UV Sensitive SiPMs
- Characterization of large area APDs for the EXO-200 detector
- Characterization of the Hamamatsu VUV4 MPPCs for nEXO
- VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
- Characterisation of Silicon Photomultipliers for Liquid Xenon Detectors
- Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment
- Characterization of SiPM Avalanche Triggering Probabilities
- Measurement of the absolute reflectance of polytetrafluoroethylene (PTFE) immersed in liquid xenon
- Large-Area MPPC with Enhanced VUV Sensitivity for Liquid Xenon Scintillation Detector
- A method for characterizing after-pulsing and dark noise of PMTs and SiPMs
- Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
- Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
- Development of low radioactivity photomultiplier tubes for the XMASS-I detector
- Cryogenic SiPM arrays for the DUNE photon detection system
- SiPM cross-talk in liquid argon detectors
- Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
- Design and construction of Xenoscope -- a full-scale vertical demonstrator for the DARWIN observatory
- Scintillation detectors with silicon photomultiplier readout in a dilution refrigerator at temperatures down to 0.2 K
- Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
- Delayed avalanches in Multi-Pixel Photon Counters
Cited by in corpus (11)
- The science and technology of liquid argon detectors
- Why would you put a flashlight in a dark matter detector?
- Front-end Electronics and Optimal Ganging Schemes for Single Photon Detection with Large Arrays of SiPMs in Liquid Argon
- Impact of extreme ultraviolet radiation on the scintillation of pure and xenon-doped liquid argon
- Supernova electron-neutrino interactions with xenon in the nEXO detector
- Measurements of the Quantum Yield of Silicon using Geiger-mode Avalanching Photodetectors
- Characterization of external cross-talk from silicon photomultipliers in a liquid xenon detector
- Canadian Contributions to the Search for Neutrinoless Double Beta Decay
- Measuring dark currents in multiple cryogenic SiPMs with sub-pA sensitivity using an automated IV multiplexer
- Xenon Signal Denoising via Supervised, Semi-Supervised, and Unsupervised Models
- Simulation Study of Photon-to-Digital Converter (PDC) Timing Specifications for LoLX Experiment