Mechanical loss and stability analysis of NEXCERA in ultra-stable optical cavities
arXiv:2409.14120 · doi:10.1364/JOSAB.578004
Abstract
NEXCERA has emerged as a ceramic-based material for spacers in ultra-stable optical cavities, with a coefficient of thermal expansion that crosses zero near room temperature. In such cavities, frequency stability is ultimately limited by Brownian thermal noise in the cavity components. A key parameter in this context is the mechanical loss, which has remained unknown for NEXCERA. In this work, we investigate the mechanical loss of NEXCERA N117B at room temperature for various resonances using the gentle nodal suspension technique. We measure a promising minimum mechanical loss of , indicating the suitability of NEXCERA for low-noise optical cavities. Using this value, we calculate the thermal noise of a cavity with a NEXCERA spacer and compare its performance to established materials such as ULE and Zerodur, taking into account different mirror substrate options. Our analysis shows that NEXCERA is a strong candidate for ultra-stable cavities due to its low thermal noise. Combined with its previously reported low linear drift, it offers a highly attractive option for long-term stable optical frequency references.
arXiv comment13 pages, 7 figures
References in corpus (47)
- Observation of Gravitational Waves from a Binary Black Hole Merger
- Thermoelastic Damping in Micro- and Nano-Mechanical Systems
- Interferometer design of the KAGRA gravitational wave detector
- A sub-40 mHz linewidth laser based on a silicon single-crystal optical cavity
- 1.5 m lasers with sub 10 mHz linewidth
- Scientific Objectives of Einstein Telescope
- Optical clock intercomparison with precision in one hour
- Modern Michelson-Morley experiment using cryogenic optical resonators
- Sub-Hz line width diode lasers by stabilization to vibrationally and thermally compensated ULE Fabry-Perot cavities
- 8E-17 fractional laser frequency instability with a long room-temperature cavity
- Titania-doped tantala/silica coatings for gravitational-wave detection
- Precision Metrology Meets Cosmology: Improved Constraints on Ultralight Dark Matter from Atom-Cavity Frequency Comparisons
- A gravitational redshift test using eccentric Galileo satellites
- Mechanical Loss in Tantala/Silica Dielectric Mirror Coatings
- Thermal expansion coefficient of single crystal silicon from 7 K to 293 K
- First observation with global network of optical atomic clocks aimed for a dark matter detection
- Tuning the Thermal Expansion Properties of Optical Reference Cavities with Fused Silica Mirrors
- Search for domain wall dark matter with atomic clocks on board global positioning system satellites
- Thermoelastic Noise and Homogeneous Thermal Noise in Finite Sized Gravitational-Wave Test Masses
- Thermal noise in optical cavities revisited
- An ultrastable silicon cavity in a continuously operating closed-cycle cryostat at 4 K
- Amorphous optical coatings of present gravitational-wave interferometers
- Cavity optomechanics with ultra-high Q crystalline micro-resonators
- Thermoelastic dissipation in inhomogeneous media: loss measurements and displacement noise in coated test masses for interferometric gravitational wave detectors
- The Science of the Einstein Telescope
- Frequency and surface dependence of the mechanical loss in fused silica
- Effect of heat treatment on mechanical dissipation in TaO coatings
- Demonstration of a time scale based on a stable optical carrier
- Cryogenic sapphire oscillator with exceptionally high long-term frequency stability
- Searching for ultra-light dark matter with optical cavities
- Low mechanical loss TiO:GeO coatings for reduced thermal noise in Gravitational Wave Interferometers
- A New Family of Light Beams and Mirror Shapes for Future LIGO Interferometers
- Measurements of a low temperature mechanical dissipation peak in a single layer of Ta2O5 doped with TiO2
- Experimental limits for low-frequency space-time fluctuations from ultrastable optical resonators
- Reducing the effect of thermal noise in optical cavities
- Investigation of mechanical losses of thin silicon flexures at low temperatures
- Resonator with ultra-high length stability as a probe for Equivalence-Principle-violating physics
- Thermoelastic relaxation in elastic structures with applications to thin plates
- BOOST -- A Satellite Mission to Test Lorentz Invariance Using High-Performance Optical Frequency References
- Thermal noise and mechanical loss of SiO/TaO optical coatings at cryogenic temperatures
- Highly reflective low-noise etalon-based meta-mirror
- On the mechanical quality factors of cryogenic test masses from fused silica and crystalline quartz
- A simplified cryogenic optical resonator apparatus providing ultra-low frequency drift
- Broadband Measurement of Coating Thermal Noise in Rigid Fabry-Perot Cavities
- Characterization of the long-term dimensional stability of a NEXCERA block using the optical resonator technique
- Potential mechanical loss mechanisms in bulk materials for future gravitational wave detectors
- Optical ultra-stable optical clock cavities as resonant mass gravitational wave detectors in search for new physics