Reducing the effect of thermal noise in optical cavities
arXiv:1212.3461 · doi:10.1007/s00340-013-5464-8
Abstract
Thermal noise in optical cavities imposes a severe limitation in the stability of the most advanced frequency standards at a level of a few 10^(-16) (s/t)^(1/2) for long averaging times t. In this paper we describe two schemes for reducing the effect of thermal noise in a reference cavity. In the first approach, we investigate the potential and limitations of operating the cavity close to instability, where the beam diameter on the mirrors becomes large. Our analysis shows that even a 10 cm short cavity can achieve a thermal noise limited fractional frequency instability in the low 10^(-16) regime. In the second approach, we increase the length of the optical cavity. We show that a 39.5 cm long cavity has the potential for a fractional frequency instability even below 10^(-16), while it seems feasible to achieve a reduced sensitivity of <10^(-10)/g for vibration-induced fractional length changes in all three directions.
arXiv comment10 pages, 6 figures, 2 tables
References in corpus (22)
- Frequency Comparison of Two High-Accuracy Al+ Optical Clocks
- A sub-40 mHz linewidth laser based on a silicon single-crystal optical cavity
- Sr lattice clock at 1x10^{-16} fractional uncertainty by remote optical evaluation with a Ca clock
- Internal thermal noise in the LIGO test masses : a direct approach
- Making optical atomic clocks more stable with level laser stabilization
- Ultrastable lasers based on vibration insensitive cavities
- Comparison of Two Independent Sr Optical Clocks with 1e-17 Stability at 10^3 s
- Rotating optical cavity experiment testing Lorentz invariance at the 10^{-17} level
- Force-insensitive optical cavity
- Thermal noise in optical cavities revisited
- Realization of a monolithic high-reflectivity cavity mirror from a single silicon crystal
- Monocrystalline AlGaAs heterostructures for high-reflectivity high-Q micromechanical resonators in the MHz regime
- Field-test of a robust, portable, frequency-stable laser
- Demonstration of a Transportable 1 Hz-Linewidth Laser
- Thermal noises and noise compensation in high-reflection multilayer coating
- Optical Interferometers with Reduced Sensitivity to Thermal Noise
- The Search for Gravitational Waves
- Reducing the mirrors coating noise in laser gravitational-wave antennae by means of double mirrors
- An Ultra-Stable Referenced Interrogation System in the Deep Ultraviolet for a Mercury Optical Lattice Clock
- A vibration-insensitive optical cavity and absolute determination of its ultrahigh stability
- Some aspects of simulation and realization of an optical reference cavity
- Reduction of coating thermal noise by using an etalon
Cited by in corpus (16)
- 8E-17 fractional laser frequency instability with a long room-temperature cavity
- Atomic Clocks for Geodesy
- Nano-Kelvin thermometry and temperature control: beyond the thermal noise limit
- A compact, thermal noise limited reference cavity for ultra-low noise microwave generation
- Progress and perspectives on composite laser-pulses spectroscopy for high-accuracy optical clocks
- Phase locking a clock oscillator to a coherent atomic ensemble
- A transportable interrogation laser system with an instability of
- Simple vibration insensitive cavity for laser stabilization at the 10^{-16} level
- Mathematical model of thermal shields for long-term stability optical resonators
- Technology for the next gravitational wave detectors
- Performance of a radiatively cooled system for quantum optomechanical experiments in space
- A tunable low-drift laser stabilized to an atomic reference
- Integrating high-precision and fringe-scale displacement sensing using heterodyne cavity-tracking
- Slow Light Frequency Reference Cavities -- Proof of Concept for Reducing the Frequency Sensitivity Due to Length Fluctuations
- Mechanical loss and stability analysis of NEXCERA in ultra-stable optical cavities
- Mirror Coating Thermal Noise Mitigation Using Multi-Spatial Mode Cavity Readout