A transportable interrogation laser system with an instability of
arXiv:2003.02766 · doi:10.1364/OE.390105
Abstract
We present an interrogation laser system for a transportable strontium lattice clock operating at 698 nm, which is based on an ultra-low-expansion glass reference cavity. Transportability is achieved by implementing a rigid, compact, and vibration insensitive mounting of the 12 cm-long reference cavity, sustaining shocks of up to 50 g. The cavity is mounted at optimized support points that independently constrain all degrees of freedom. This mounting concept is especially beneficial for cavities with a ratio of length over diameter . Generally large helps to reduce thermal noise-induced laser frequency instability while small leads to small cavity volume. The frequency instability was evaluated, reaching its thermal noise floor of for averaging times between 0.5 s and 10 s. The laser system was successfully operated during several field studies.
References in corpus (20)
- 1.5 m lasers with sub 10 mHz linewidth
- Geodesy and metrology with a transportable optical clock
- Optical clock intercomparison with precision in one hour
- Ultra-stable optical clock with two cold-atom ensembles
- 8E-17 fractional laser frequency instability with a long room-temperature cavity
- Atomic Clocks for Geodesy
- A transportable optical lattice clock with uncertainty
- Tuning the Thermal Expansion Properties of Optical Reference Cavities with Fused Silica Mirrors
- Force-insensitive optical cavity
- Thermal noise in optical cavities revisited
- Noise and instability of an optical lattice clock
- A compact, robust, and transportable ultra-stable laser with a fractional frequency instability of
- Demonstration of a Transportable 1 Hz-Linewidth Laser
- A cavity-stabilized laser with acceleration sensitivity below /g
- Delivering pulsed and phase stable light to atoms of an optical clock
- A compact, thermal noise limited reference cavity for ultra-low noise microwave generation
- Reducing the effect of thermal noise in optical cavities
- Photothermal and thermo-refractive effects in high reflectivity mirrors at room and cryogenic temperature
- Ultra-compact reference ULE cavity
- Development of a strontium optical lattice clock for the SOC mission on the ISS
Cited by in corpus (10)
- Point-to-Point Stabilised Optical Frequency Transfer with Active Optics
- Prospects and challenges for squeezing-enhanced optical atomic clocks
- A transportable clock laser system with an instability of
- Long-distance chronometric leveling with a portable optical clock
- Thermal noise and mechanical loss of SiO/TaO optical coatings at cryogenic temperatures
- Digital Doppler-cancellation servo for ultra-stable optical frequency dissemination over fiber
- Phase-stabilized UV light at 267 nm through twofold second harmonic generation
- A laser with instability reaching based on a 10-cm-long silicon cavity at sub-5-K temperatures
- Ultra-stable transportable ultraviolet clock laser using cancellation between photo-thermal and photo-birefringence noise
- Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map