A laser with instability reaching based on a 10-cm-long silicon cavity at sub-5-K temperatures
arXiv:2510.06636 · doi:10.1016/j.scib.2025.08.050
Abstract
The realization of ultra-stable lasers with -level frequency stability has enabled a wide range of researches on precision metrology and fundamental science, where cryogenic single-crystalline cavities constitute the heart of such ultra-stable lasers. For further improvements in stability, increasing the cavity length at few-kelvin temperatures provides a promising alternative to utilizing relatively short cavities with novel coating, but has yet to be demonstrated with state-of-the-art stability. Here we report on the realization of a relatively long ultra-stable silicon cavity with a length of 10 cm and sub-5-K operating temperatures. We devise a dynamical protocol of cool-quiet quench measurement that reveals the inherent -level frequency instability of the silicon cavity despite the substantially larger frequency noise induced by the cryostat vibration. We further develop a method for suppressing the cryostat-vibration-induced frequency noise under continuous cooling, and observe an average frequency instability of for averaging times of 4 to 12 seconds. Using the measured noise power spectral density, we compute a median linewidth of 9.6(3) mHz for the silicon cavity laser at 1397 nm, which is supported by an empirically determined linewidth of 5.7(3) mHz based on direct optical beat measurements. These results establish a new record for optical cavities within a closed-cycle cryocooler at sub-5-K temperatures and provide a prototypical system for using long cryogenic cavities to enhance frequency stabilities to the low- or better level.
arXiv commenthttps://doi.org/10.1016/j.scib.2025.08.050
References in corpus (18)
- Atomic clock performance beyond the geodetic limit
- 1.5 m lasers with sub 10 mHz linewidth
- Optical clock intercomparison with precision in one hour
- Resolving the gravitational redshift within a millimeter atomic sample
- Gravitational wave detection with optical lattice atomic clocks
- New Limits on Coupling of Fundamental Constants to Gravity Using Sr Optical Lattice Clocks
- High precision differential clock comparisons with a multiplexed optical lattice clock
- Force-insensitive optical cavity
- An ultrastable silicon cavity in a continuously operating closed-cycle cryostat at 4 K
- SAGE: A Proposal for a Space Atomic Gravity Explorer
- Optical spectrum analyzer with quantum limited noise floor
- Excess noise and photo-induced effects in highly reflective crystalline mirror coatings
- A transportable interrogation laser system with an instability of
- Thermal noise and mechanical loss of SiO/TaO optical coatings at cryogenic temperatures
- Substrate-transferred GaAs/AlGaAs crystalline coatings for gravitational-wave detectors: A review of the state of the art
- An ultra-stable cryogenic sapphire cavity laser with an instability of based on a low vibration level cryostat
- Synthetic FM triplet for AM-free precision laser stabilization and spectroscopy
- A silicon single-crystal cryogenic optical resonator