Broadband Measurement of Coating Thermal Noise in Rigid Fabry-Perot Cavities
arXiv:1406.4467 · doi:10.1088/0026-1394/52/1/17
Abstract
We report on the relative length fluctuation of two fixed-spacer Fabry-Perot cavities with mirrors fabricated from silica/tantala dielectric coatings on fused silica substrates. By locking a laser to each cavity and reading out the beat note of the transmitted beams, we find that, for frequencies from 10 Hz to 1 kHz, the amplitude spectral density of beat note fluctuation is $\sqrt{S_\hatν(f)} = (0.5\,\mathrm{Hz})/f^{1/2}$. By careful budgeting of noise sources contributing to the beat note, we find that our measurement is consistent with the fluctuation in this band being dominated by the Brownian noise of the mirror coatings. Fitting for the coating loss angle , we find it equal to . We then use a Bayesian analysis to combine our measurement with previous observations, and thereby extract estimates for the individual loss angles of silica and tantala. It is hoped that the testbed described in this article can be used in the future to measure the length noise of cavities formed with novel mirror materials and geometries.
arXiv comment14 pages, 13 figures
References in corpus (23)
- A sub-40 mHz linewidth laser based on a silicon single-crystal optical cavity
- Internal thermal noise in the LIGO test masses : a direct approach
- Compact, thermal-noise-limited optical cavity for diode laser stabilization at 1 x 10-15
- Thermal noise in interferometric gravitational wave detectors due to dielectric optical coatings
- Sub-Hz line width diode lasers by stabilization to vibrationally and thermally compensated ULE Fabry-Perot cavities
- Gravitational Radiation Detection with Laser Interferometry
- Ultrastable lasers based on vibration insensitive cavities
- Thermodynamical fluctuations and photo-thermal shot noise in gravitational wave antennae
- Titania-doped tantala/silica coatings for gravitational-wave detection
- Mechanical Loss in Tantala/Silica Dielectric Mirror Coatings
- Thermo-refractive noise in gravitational wave antennae
- Thermoelastic Noise and Homogeneous Thermal Noise in Finite Sized Gravitational-Wave Test Masses
- Thermo-optic noise in coated mirrors for high-precision optical measurements
- Thermal noise in optical cavities revisited
- Thermoelastic effects at low temperatures and quantum limits in displacement measurements
- Thermoelastic dissipation in inhomogeneous media: loss measurements and displacement noise in coated test masses for interferometric gravitational wave detectors
- Brownian Thermal Noise in Multilayer Coated Mirrors
- Thermal noise in half infinite mirrors with non-uniform loss: a slab of excess loss in a half infinite mirror
- Fluctuation-dissipation theorem for thermo-refractive noise
- Direct Observation of Broadband Coating Thermal Noise in a Suspended Interferometer
- Measurements of mechanical thermal noise and energy dissipation in optical dielectric coatings
- Photothermal and thermo-refractive effects in high reflectivity mirrors at room and cryogenic temperature
- Coating thermal noise of a finite-size cylindrical mirror
Cited by in corpus (9)
- Review of the Advanced LIGO gravitational wave observatories leading to observing run four
- Searching for ultra-light dark matter with optical cavities
- Coherent Cancellation of Photothermal Noise in GaAs/AlGaAs Bragg Mirrors
- Audio-band Coating Thermal Noise Measurement for Advanced LIGO with a Multi-mode Optical Resonator
- Laser Frequency Noise in Next Generation Gravitational-Wave Detectors
- Thermal noise and mechanical loss of SiO/TaO optical coatings at cryogenic temperatures
- Thermorefringent noise in crystalline optical materials
- Quantum-enhanced optical phase-insensitive heterodyne detection beyond 3-dB noise penalty of image band
- Mechanical loss and stability analysis of NEXCERA in ultra-stable optical cavities