A simplified cryogenic optical resonator apparatus providing ultra-low frequency drift
arXiv:2004.01552 · doi:10.1063/1.5140321
Abstract
A system providing an optical frequency with an instability comparable to that of a hydrogen maser is presented. It consists of a long, vertically oriented silicon optical resonator operated at temperatures between and in a closed-cycle cryostat with low-temperature Joule-Thomson stage. We show that with a standard cryostat, a simple cryogenic optomechanical setup, no active or passive vibration isolation, a minimum frequency instability of at integration time can be reached. The influence of pulse-tube vibrations was minimized by using a resonator designed for low acceleration sensitivity. With reduced optical laser power and interrogation duty cycle an ultra-low fractional frequency drift of / is reached. At the resonator frequency exhibits a vanishing thermal sensitivity and an ultra-small temperature derivative . These are favorable properties that should lead to high performance also in simpler cryostats not equipped with a Joule-Thomson stage.
References in corpus (14)
- The Confrontation between General Relativity and Experiment
- A sub-40 mHz linewidth laser based on a silicon single-crystal optical cavity
- 1.5 m lasers with sub 10 mHz linewidth
- Compact, thermal-noise-limited optical cavity for diode laser stabilization at 1 x 10-15
- Gravitational Radiation Detection with Laser Interferometry
- 8E-17 fractional laser frequency instability with a long room-temperature cavity
- Colloquium: Physics of optical lattice clocks
- An ultrastable silicon cavity in a continuously operating closed-cycle cryostat at 4 K
- Direct Terrestrial Test of Lorentz Symmetry in Electrodynamics to 10
- Testing Local Lorentz and Position Invariance and Variation of Fundamental Constants by searching the Derivative of the Comparison Frequency Between a Cryogenic Sapphire Oscillator and Hydrogen Maser
- Ultra-stable laser with average fractional frequency drift rate below
- A compact, robust, and transportable ultra-stable laser with a fractional frequency instability of
- A compact, thermal noise limited reference cavity for ultra-low noise microwave generation
- Resonator with ultra-high length stability as a probe for Equivalence-Principle-violating physics
Cited by in corpus (3)
- An ultra-stable cryogenic sapphire cavity laser with an instability of based on a low vibration level cryostat
- Optical ultra-stable optical clock cavities as resonant mass gravitational wave detectors in search for new physics
- Mechanical loss and stability analysis of NEXCERA in ultra-stable optical cavities