Robust operation of a GaAs tunable barrier electron pump
arXiv:1810.00100 · doi:10.1088/1681-7575/aa634c
Abstract
We demonstrate the robust operation of a gallium arsenide tunable-barrier single-electron pump operating with 1 part-per-million accuracy at a temperature of ~K and a pumping frequency of ~MHz. The accuracy of current quantisation is investigated as a function of multiple control parameters, and robust plateaus are seen as a function of three control gate voltages and RF drive power. The electron capture is found to be in the decay-cascade, rather than the thermally-broadened regime. The observation of robust plateaus at an elevated temperature which does not require expensive refrigeration is an important step towards validating tunable-barrier pumps as practical current standards.
arXiv comment13 pages, 7 figures (4 in main text and 3 in supplementary info
References in corpus (14)
- Single-electron current sources: towards a refined definition of ampere
- Towards a quantum representation of the ampere using single electron pumps
- Non-adiabatic quantized charge pumping with tunable-barrier quantum dots: a review of current progress
- Universal decay cascade model for dynamic quantum dot initialization
- Validation of a quantized-current source with 0.2 ppm uncertainty
- Robust single-parameter quantized charge pumping
- Counting statistics for electron capture in a dynamic quantum dot
- Single-parameter quantized charge pumping in high magnetic fields
- Stabilization of single-electron pumps by high magnetic fields
- Accurate high speed single-electron quantum dot preparation
- Enhanced current quantization in high frequency electron pumps in a perpendicular magnetic field
- Validation of the ultrastable low-noise current amplifier as travelling standard for small direct currents
- Rectification in mesoscopic AC-gated semiconductor devices
- Modeling of a tunable-barrier non-adiabatic electron pump beyond the decay cascade model
Cited by in corpus (9)
- Evidence for universality of tunable-barrier electron pumps
- Thermal-error regime in high-accuracy gigahertz single-electron pumping
- Gigahertz Single-Electron Pumping Mediated by Parasitic States
- Inter-laboratory nanoamp current comparison with sub-part-per-million uncertainty
- Re-evaluation of uncertainty for calibration of M and G resistors at NPL
- Non-adiabatic single-electron pump in a dopant-free GaAs/AlGaAs 2DEG
- Mitigating decoherence in hot electron interferometry
- Single-Hole Pump in Germanium