Cross-calibrating X-ray detectors with clusters of galaxies: an IACHEC study
arXiv:1008.2102 · doi:10.1051/0004-6361/201015176
Abstract
We used a sample of 11 nearby relaxed clusters of galaxies observed with the X-ray instruments XMM-Newton (EPIC) pn and MOS, Chandra ACIS-S and ACIS-I and BeppoSAX MECS to examine the cross-calibration of the energy dependence and normalisation of the effective area of these instruments as of December 2009. We also examined the Fe XXV/XXVI line ratio temperature measurement method for the pn and MOS. We performed X-ray spectral analysis on the XMM-Newton and Chandra data for a sample of 11 clusters. We obtained the information for BeppoSAX from DeGrandi & Molendi (2002). We compared the spectroscopic results obtained with different instruments for the same clusters in order to examine possible systematic calibration effects between the instruments. We did not detect any significant systematic differences between the temperatures derived in the 2-7 keV band using the different instruments. Also, the EPIC temperatures derived from the bremsstrahlung continuum agreed with those obtained from the Fe XXV/XXVI emission line ratio, implying that the energy dependence of the hard band effective area of the above instruments is accurately calibrated. On the other hand, the hard band EPIC/ACIS fluxes disagreed by 5-10% (i.e. at 6-25 sigma level) which indicates a similar level of uncertainty in the normalisations of the effective areas of these instruments in the 2--7 keV band. In the soft energy band (0.5-2.0 keV) there are greater cross-calibration differences between EPIC and ACIS. Due to the high statistical weight of the soft band data, the 0.5-7.0 keV band temperature measurements of clusters of galaxies with EPIC or ACIS are uncertain by ~10-15% on average.
Accepted for publication in Astronomy & Astrophysics
References in corpus (4)
- Chandra temperature profiles for a sample of nearby relaxed galaxy clusters
- A Catalog of Galaxy Clusters Observed by XMM-Newton
- Statistical evaluation of the flux cross-calibration of the XMM-Newton EPIC cameras
- An analysis of electron distributions in galaxy clusters by means of the flux ratio of iron lines FeXXV and XXVI
Cited by in corpus (79)
- Galaxy Cluster Baryon Fractions Revisited
- The galaxy cluster mass scale and its impact on cosmological constraints from the cluster population
- NuSTAR Observations of the Bullet Cluster: Constraints on Inverse Compton Emission
- Joint Analysis of Cluster Observations: II. Chandra/XMM-Newton X-ray and Weak Lensing Scaling Relations for a Sample of 50 Rich Clusters of Galaxies
- Lensing and X-ray mass estimates of clusters (SIMULATION)
- On the nature of hydrostatic equilibrium in galaxy clusters
- Non-thermal pressure support in X-COP galaxy clusters
- XMM-Newton and Chandra Cross Calibration Using HIFLUGCS Galaxy Clusters: Systematic Temperature Differences and Cosmological Impact
- Mass profiles of Galaxy Clusters from X-ray analysis
- Improved Mass and Radius Constraints for Quiescent Neutron Stars in Omega Cen and NGC 6397
- NuSTAR Spectroscopy of Multi-Component X-ray Reflection from NGC 1068
- Growth of Cosmic Structure: Probing Dark Energy Beyond Expansion
- The 2-79 keV X-ray Spectrum of the Circinus Galaxy with NuSTAR, XMM-Newton and Chandra: a Fully Compton-Thick AGN
- CLASH-X: A Comparison of Lensing and X-ray Techniques for Measuring the Mass Profiles of Galaxy Clusters
- MUSTANG High Angular Resolution Sunyaev-Zel'dovich Effect Imaging of Sub-Structure in Four Galaxy Clusters
- IACHEC Cross-Calibration of Chandra, NuSTAR, Swift, Suzaku, and XMM-Newton with 3C 273 and PKS 2155-304
- Cross-calibration of the X-ray Instruments onboard the Chandra, INTEGRAL, RXTE, Suzaku, Swift, and XMM-Newton Observatories using G21.5-0.9
- The XXL Survey. XIII. Baryon content of the bright cluster sample
- Hot Gas in Galaxy Groups: Recent Observations
- A Measurement of the Kinetic Sunyaev-Zel'dovich Signal Toward MACS J0717.5+3745
- Cosmology and astrophysics from relaxed galaxy clusters - IV: Robustly calibrating hydrostatic masses with weak lensing
- Scaling Properties of Galaxy Groups
- Comparing Masses in Literature (CoMaLit)-I. Bias and scatter in weak lensing and X-ray mass estimates of clusters
- LoCuSS: Hydrostatic Mass Measurements of the High- Cluster Sample -- Cross-calibration of Chandra and XMM-Newton
- SNR 1E 0102.2-7219 as an X-ray Calibration Standard in the 0.5-1.0 keV Bandpass and Its Application to the CCD Instruments aboard Chandra, Suzaku, Swift and XMM-Newton
- The XMM Cluster Outskirts Project (X-COP): Physical conditions to the virial radius of Abell 2142
- Galaxy Cluster Scaling Relations between Bolocam Sunyaev-Zel'dovich Effect and Chandra X-ray Measurements
- The pressure profiles of hot gas in local galaxy groups
- High Resolution XMM-Newton Spectroscopy of the Cooling Flow Cluster A3112
- The 400d Galaxy Cluster Survey weak lensing programme: III: Evidence for consistent WL and X-ray masses at
- The gravitational field of X-COP galaxy clusters
- Iron in X-COP: tracing enrichment in cluster outskirts with high accuracy abundance profiles
- A Comparative Study of Local Galaxy Clusters: I. Derived X-ray Observables
- Neutrino constraints: what large-scale structure and CMB data are telling us?
- X-ray Bright Active Galactic Nuclei in Massive Galaxy Clusters I: Number Counts and Spatial Distribution
- Temperature Structure in the Perseus Cluster Core Observed with Hitomi
- The Long-Term X-Ray Variability of Broad Absorption Line Quasars
- Metal distribution in sloshing galaxy clusters: the case of A496
- Weak Lensing Calibrated M-T Scaling Relation of Galaxy Groups in the COSMOS Field
- Chandra Measurements of a Complete Sample of X-ray Luminous Galaxy Clusters: The Luminosity-Mass Relation
- Mass/Radius Constraints on the Quiescent Neutron Star in M13 Using Hydrogen and Helium Atmospheres
- Chandra X-ray observations of Abell 1835 to the virial radius
- Probing the Milky Way's Dark Matter Halo for the 3.5 keV Line
- Deriving the Hubble constant using Planck and XMM-Newton observations of galaxy clusters
- Cool core disturbed: Observational evidence for coexistence of sub-sonic sloshing gas and stripped shock-heated gas around the core of RX J1347.5-1145
- Cross-calibration of Suzaku XIS and XMM-Newton EPIC using clusters of galaxies
- Shape and orientation of the gas distribution in A1689
- New insights into the evolution of the FR I radio galaxy 3C 270 (NGC 4261) from VLA and GMRT radio observations
- Reconciling Planck cluster counts and cosmology? Chandra/XMM instrumental calibration and hydrostatic mass bias
- The Lack of Diffuse, Nonthermal Hard X-ray Emission in the Coma Cluster: The Swift BAT's Eye View
- The Atacama Cosmology Telescope: High-Resolution Sunyaev-Zel'dovich Array Observations of ACT SZE-selected Clusters from the Equatorial Strip
- Chandra Follow-Up of the SDSS DR8 redMaPPer Catalog Using the MATCha Pipeline
- The SRG/eROSITA All-Sky Survey: SRG/eROSITA cross-calibration with Chandra and XMM-Newton using galaxy cluster gas temperatures
- A multiwavelength-motivated X-ray model for the Circinus Galaxy
- Measuring using X-ray and SZ effect observations of dynamically relaxed galaxy clusters
- A Chandra search for the pulsar wind nebula around PSR B1055-52
- X-ray Observations of Complex Temperature Structure in the Cool-core cluster Abell 85
- An XMM-Newton view of the merging activity in the Centaurus cluster
- A Systematic Comparison of Galaxy Cluster Temperatures Measured with NuSTAR and Chandra
- A Chandra Study of Radial Temperature Profiles of the Intra-Cluster Medium in 50 Galaxy Clusters
- Search for a Non-equilibrium Plasma in the Merging Galaxy Cluster Abell 754
- A New Interpretation of the Mass-Temperature Relation and Mass Calibration of Galaxy Clusters Based on the Fundamental Plane
- The Exceptional X-ray Evolution of SN1996cr in High Resolution
- Concordance: In-flight Calibration of X-ray Telescopes without Absolute References
- Soft X-ray emission from warm gas in IllustrisTNG circum-cluster environments
- Systematic Uncertainties in the Spectroscopic Measurements of Neutron-Star Masses and Radii from Thermonuclear X-ray Bursts. III. Absolute Flux Calibration
- Probing supermassive black hole growth and its dependence on stellar mass and star-formation rate in low-redshift galaxies
- Scaling relations of clusters and groups, and their evolution
- The X-ray Decay of the ultraluminous supernova SN 1978K in NGC 1313
- X-ray and near-infrared observations of the middle-aged pulsar B1055-52, its multiwavelength spectrum, and proper motion
- Deprojected analysis of Abell 1835 observed with Chandra and compared with XMM-Newton
- Unbiased Correction Relations for Galaxy Cluster properties Derived from Chandra and XMM-Newton
- Detection of pure warm-hot intergalactic medium emission from a Mpc long filament in the Shapley supercluster using X-ray spectroscopy
- X-ray spectroscopy of Abell S1101 with Chandra, XMM-Newton and ROSAT: band-pass dependence of he temperature profile and soft excess emission
- Resolving high-z Galaxy Cluster properties through joint X-ray and Millimeter analysis: a case study of SPT-CLJ0615-5746
- Calibration Concordance for Astronomical Instruments via Multiplicative Shrinkage
- Cross Calibration of Galaxy Cluster Temperatures Measured with NuSTAR, XMM-Newton, and Chandra
- The thermodynamic structure and large-scale structure filament in MACS J0717.5+3745
- The XMM-BCS galaxy cluster survey: I. The X-ray selected cluster catalog from the initial 6 deg