747 citations · 3.9k across the 55 of their papers we have counts for
29 papers · 1 filter
Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity
LUX Collaboration, D. S. Akerib, S. Alsum +94
Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability…
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
J. Aalbers, K. Abe, V. Aerne +591
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leadi…
Characterization of the scintillation time response of liquid argon detectors for dark matter search
P. Agnes, S. De Cecco, A. Fan +17
The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejecti…
Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber
R. Linehan, R. L. Mannino, A. Fan +46
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless do…
Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of Xe
The LUX-ZEPLIN, Collaboration, : +194
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of Xe is presented. LZ is a 10-tonne xenon time projection ch…
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +387
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above cm for a WIMP mass…
Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
LUX Collaboration, D. S. Akerib, S. Alsum +94
We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 20…
Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment
ZEPLIN Collaboration, D. S. Akerib, C. W. Akerlof +194
The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)\,pb at a WIMP mass of 40 GeV/…
Improved Modeling of Electronic Recoils in Liquid Xenon Using LUX Calibration Data
The LUX Collaboration, D. S. Akerib, S. Alsum +96
We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-pro…
Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
D. S. Akerib, S. Alsum, H. M. Araújo +98
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from inje…
LUX Trigger Efficiency
D. S. Akerib, S. Alsum, H. M. Araújo +94
The Large Underground Xenon experiment (LUX) searches for dark matter using a dual-phase xenon detector. LUX uses a custom-developed trigger system for event selection. In this pap…
Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector
The LUX Collaboration, D. S. Akerib, S. Alsum +90
Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection cham…
Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC
P. Agnes, I. F. M. Albuquerque, T. Alexander +163
We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift elec…
Measurement of the liquid argon energy response to nuclear and electronic recoils
P. Agnes, J. Dawson, S. De Cecco +26
A liquid argon time projection chamber, constructed for the Argon Response to Ionization and Scintillation (ARIS) experiment, has been exposed to the highly collimated and quasi-mo…
Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment
D. S. Akerib, S. Alsum, H. M. Araújo +95
The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sectio…
Position Reconstruction in LUX
LUX Collaboration, D. S. Akerib, S. Alsum +91
The position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a…
Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture
LUX Collaboration, D. S. Akerib, S. Alsum +91
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 3…
3D Modeling of Electric Fields in the LUX Detector
LUX Collaboration, D. S. Akerib, S. Alsum +91
This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacti…
Kr calibration of the 2013 LUX dark matter search
LUX Collaboration, D. S. Akerib, S. Alsum +91
LUX was the first dark matter experiment to use a Kr calibration source. In this paper we describe the source preparation and injection. We also present several $^…
The Electronics, Trigger and Data Acquisition System for the Liquid Argon Time Projection Chamber of the DarkSide-50 Search for Dark Matter
DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque +177
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon a…
Simulation of argon response and light detection in the DarkSide-50 dual phase TPC
The DarkSide Collaboration, P. Agnes, I. F. M. Albuquerque +147
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP intera…
LUX-ZEPLIN (LZ) Technical Design Report
B. J. Mount, S. Hans, R. Rosero +259
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achi…
Feasibility study of SiGHT: a novel ultra low background photosensor for low temperature operation
Yi Wang, Alden Fan, Giuliana Fiorillo +10
Rare event search experiments, such as those searching for dark matter and observations of neutrinoless double beta decay, require ultra low levels of radioactive background for un…
Effect of Low Electric Fields on Alpha Scintillation Light Yield in Liquid Argon
P. Agnes, I. F. M. Albuquerque, T. Alexander +158
Measurements were made of scintillation light yield of alpha particles from the Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield…