Measurement of the liquid argon energy response to nuclear and electronic recoils
arXiv:1801.06653 · doi:10.1103/PhysRevD.97.112005
Abstract
A liquid argon time projection chamber, constructed for the Argon Response to Ionization and Scintillation (ARIS) experiment, has been exposed to the highly collimated and quasi-monoenergetic LICORNE neutron beam at the Institute de Physique Nuclaire Orsay in order to study the scintillation response to nuclear and electronic recoils. An array of liquid scintillator detectors, arranged around the apparatus, tag scattered neutrons and select nuclear recoil energies in the [7, 120] keV energy range. The relative scintillation efficiency of nuclear recoils was measured to high precision at null field, and the ion-electron recombination probability was extracted for a range of applied electric fields. Single Compton scattered electrons, produced by gammas emitted from the de-excitation of Li* in coincidence with the beam pulse, along with calibration gamma sources, are used to extract the recombination probability as a function of energy and electron drift field. The ARIS results have been compared with three recombination probability parameterizations (Thomas-Imel, Doke-Birks, and PARIS), allowing for the definition of a fully comprehensive model of the liquid argon response to nuclear and electronic recoils down to a few keV range. The constraints provided by ARIS to the liquid argon response at low energy allow the reduction of systematics affecting the sensitivity of dark matter search experiments based on liquid argon
arXiv comment15 pages, 20 figures
References in corpus (12)
- Results from a search for dark matter in the complete LUX exposure
- Dark Matter Results from First 98.7-day Data of PandaX-II Experiment
- Results from the first use of low radioactivity argon in a dark matter search
- Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment
- Measurement of Scintillation and Ionization Yield and Scintillation Pulse Shape from Nuclear Recoils in Liquid Argon
- A Model of Nuclear Recoil Scintillation Efficiency in Noble Liquids
- Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1
- Measurement of scintillation efficiency for nuclear recoils in liquid argon
- First measurement of the ionization yield of nuclear recoils in liquid argon
- Simulation of argon response and light detection in the DarkSide-50 dual phase TPC
- Calibration of liquid argon and neon detectors with
- Scintillation efficiency of liquid argon in low energy neutron-argon scattering
Cited by in corpus (26)
- Low-Mass Dark Matter Search with the DarkSide-50 Experiment
- First Measurement of Coherent Elastic Neutrino-Nucleus Scattering on Argon
- Migdal effect and photon Bremsstrahlung: improving the sensitivity to light dark matter of liquid argon experiments
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Sensitivity of the COHERENT Experiment to Accelerator-Produced Dark Matter
- Constraining active-sterile neutrino transition magnetic moments at DUNE near and far detectors
- Properties of Liquid Argon Scintillation Light Emission
- First Constraint on Coherent Elastic Neutrino-Nucleus Scattering in Argon
- Sensitivity of future liquid argon dark matter search experiments to core-collapse supernova neutrinos
- Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
- Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50
- LArQL: A phenomenological model for treating light and charge generation in liquid argon
- Neutrino Backgrounds in Future Liquid Noble Element Dark Matter Direct Detection Experiments
- Predicting Transport Effects of Scintillation Light Signals in Large-Scale Liquid Argon Detectors
- Measurement of the scintillation efficiency for nuclear recoils in liquid argon under electric fields up to 3 kV/cm
- Liquid argon light collection and veto modeling in GERDA Phase II
- Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC
- Liquid argon scintillation response to electronic recoils between -- in a high light yield single-phase detector
- Study of visible-light emission in pure and methane-doped liquid argon
- Characterization of the scintillation time response of liquid argon detectors for dark matter search
- Scintillation and Ionization Ratio of Liquid Argon for Electronic and Nuclear Recoils at Drift-Fields up to 3 kV/cm
- Relative Measurement and Extrapolation of the Scintillation Quenching Factor of -Particles in Liquid Argon using DEAP-3600 Data
- Calibration of liquid argon detector with and in different drift field
- Scintillation light detection in the long-drift ProtoDUNE-DP liquid argon TPC
- Characterization of argon recoils at the keV scale with ReD and ReD+
- Performance of the ReD TPC, a novel double-phase LAr detector with Silicon Photomultiplier Readout