Measurement of the scintillation efficiency for nuclear recoils in liquid argon under electric fields up to 3 kV/cm
arXiv:1902.01501 · doi:10.1103/PhysRevD.100.032002
Abstract
We present a measurement of scintillation efficiency for a few tens of keV nuclear recoils (NR) with a liquid argon time projection chamber under electric fields ranging from to . The calibration data are taken with radioactive source. Observed scintillation and electroluminescence spectra are simultaneously fit with spectra derived from Geant4-based Monte Carlo simulation and an NR model. The scintillation efficiency extracted from the fit is reported as a function of recoil energy and electric field. This result can be used for designing the detector and for the interpretation of experimental data in searching for scintillation and ionization signals induced by WIMP dark matter.
arXiv comment8 pages, 12 figures
References in corpus (16)
- Low-Mass Dark Matter Search with the DarkSide-50 Experiment
- DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon
- The GERDA experiment for the search of 0νββ decay in ^{76}Ge
- First results from a Dark Matter search with liquid Argon at 87 K in the Gran Sasso Underground Laboratory
- Measurement of Scintillation and Ionization Yield and Scintillation Pulse Shape from Nuclear Recoils in Liquid Argon
- First results from the DEAP-3600 dark matter search with argon at SNOLAB
- A Model of Nuclear Recoil Scintillation Efficiency in Noble Liquids
- A Global Analysis of Light and Charge Yields in Liquid Xenon
- WARP liquid argon detector for dark matter survey
- Measurement of the liquid argon energy response to nuclear and electronic recoils
- Measurement of scintillation efficiency for nuclear recoils in liquid argon
- First measurement of the ionization yield of nuclear recoils in liquid argon
- Simulation of argon response and light detection in the DarkSide-50 dual phase TPC
- Scintillation efficiency of liquid argon in low energy neutron-argon scattering
- New libraries for simulating neutron scattering in dark matter detector calibrations
- Scintillation and Ionization Ratio of Liquid Argon for Electronic and Nuclear Recoils at Drift-Fields up to 3 kV/cm
Cited by in corpus (5)
- A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
- Nuclear Fusion Inside Dark Matter
- Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique
- Lindhard integral equation with binding energy applied to light and charge yields of nuclear recoils in noble liquid detectors
- Searching for low-mass dark matter via Migdal effect in COSINE-100