activity
20152026
most citedPositronium imaging with the novel multiphoton PET scanner

185 citations · 1k across the 46 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

23 papers · 1 filter

physics.ins-det2026

Pulse-shape discrimination with machine learning for CZT detectors at the DANE beam test facility

Simone Manti, Francesco Artibani, Leonardo Abbene +36

Cadmium zinc telluride (CZT) detectors offer versatility, operational simplicity, and room-temperature X- and gamma-ray spectroscopy, making them attractive for collider applicatio…

physics.ins-det2024★ 1 cited

First Linearity and Stability Characterization for CZT Detection System in a ee Collider Environment

Leonardo Abbene, Francesco Artibani, Manuele Bettelli +40

The SIDDHARTA-2 collaboration built a new cadmium-zinc-telluride (CZT, CdZnTe)-based X-ray detection system, used for the first time in the DANE electron-positron collider at IN…

physics.ins-det2024★ 12 cited

Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

L. Kaplon, J. Baran, N. Chug +31

Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpo…

physics.ins-det2023

Feasibility studies for imaging ee annihilation with modular multi-strip detectors

S. Sharma, L. Povolo, S. Mariazzi +41

Studies based on imaging the annihilation of the electron (e) and its antiparticle positron (e) open up several interesting applications in nuclear medicine and fundame…

physics.ins-det2023★ 6 cited

J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams

S. Sharma, J. Baran, R. S. Brusa +33

The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 p…

physics.ins-det2021★ 105 cited

Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators

Paweł Moskal, Paweł Kowalski, Roman Shopa +26

The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scinti…

physics.ins-det2020★ 17 cited

Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view

P. Moskal, T. Bednarski, Sz. Niedzwiecki +36

Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a…

physics.ins-det2020★ 31 cited

The J-PET detector -- a tool for precision studies of ortho-positronium decays

K. Dulski, S. D. Bass, J. Chhokar +41

The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measuremen…

physics.ins-det2020

Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts

N. G. Sharma, M. Silarski, J. Chhokar +32

In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recen…

physics.ins-det2019★ 3 cited

Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner

S. Sharma, J. Chhokar, C. Curceanu +36

Time-Over-Threshold (TOT) technique is being used widely due to its implications in developing the multi channel readouts mainly when fast signal processing is required. Using TOT…

physics.ins-det2019

Performance assessment of the 2 positronium imaging with the total-body PET scanners

P. Moskal, D. Kisielewska, Z. Bura +39

In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue,…

physics.ins-det2019★ 1 cited

Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph

N. Krawczyk, B. C. Hiesmayr, C. Curceanu +31

J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such…

physics.ins-det2018★ 55 cited

Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector

P. Moskal, N. Krawczyk, B. C. Hiesmayr +31

J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scatter…

physics.ins-det2018★ 14 cited

Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy

K. Dulski, C. Curceanu, E. Czerwiński +30

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for s…

physics.ins-det2018★ 3 cited

A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector

J. Raj, A. Gajos, C. Curceanu +31

The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an…

physics.ins-det2018★ 55 cited

Estimating the NEMA characteristics of the J-PET tomograph using the GATE package

Paweł Kowalski, Wojciech Wiślicki, Roman Shopa +30

The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of…

physics.ins-det2018★ 96 cited

Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices

G. Korcyl, P. Białas, C. Curceanu +36

A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no…

physics.ins-det2018★ 142 cited

Feasibility study of the positronium imaging with the J-PET tomograph

P. Moskal, D. Kisielewska, C. Curceanu +27

A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy of 511 keV, and it gives information on the densi…

physics.ins-det2018★ 1 cited

Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector

A. Gajos, C. Curceanu, E. Czerwiński +29

This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The…

physics.ins-det2017★ 14 cited

Analysis procedure of the positronium lifetime spectra for the J-PET detector

K. Dulski, B. Zgardzinska, P. Bialas +30

Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices…

physics.ins-det2017★ 3 cited

Time calibration of the J-PET detector

M. Skurzok, M. Silarski, D. Alfs +32

The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the firs…

physics.ins-det2016★ 71 cited

A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

D. Kamińska, A. Gajos, E. Czerwiński +26

We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PE…

physics.ins-det2015★ 3 cited

Recovery Time Measurements of Silicon Photomultipliers Using a Pulsed Laser

L. Gruber, S. E. Brunner, C. Curceanu +5

We performed an experimental study to determine the pixel recovery time of various Multi Pixel Photon Counters (MPPCs) in order to characterize their rate capability and double-hit…