Abstract
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisition system and analysis software were used to precisely characterize these parameters. We demonstrate that FBK RGB-HD SiPMs with low quenching resistance (RGB-HD-LR) can be operated from 40 K to 300 K with gains in the range to and noise rates on the order of a few Hz/mm.
References in corpus (2)
Cited by in corpus (9)
- Characterisation of SiPMs
- Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
- SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
- Direct comparison of PEN and TPB wavelength shifters in a liquid argon detector
- Characterization of VUV4 SiPM for Liquid Argon Detector
- First operation of undoped CsI directly coupled with SiPMs at 77 Kelvin
- The DarkSide-20k experiment
- A large facility for photosensors test at cryogenic temperature
- Batch VUV4 Characterization for the SBC-LAr10 scintillating bubble chamber