Ultrasensitive Inverse Weak-Value Tilt Meter
arXiv:1701.05208 · doi:10.1364/OL.42.002479
Abstract
We present an interferometric technique for measuring ultra-small tilts. The information of a tilt in one of the mirrors of a modified Sagnac interferometer is carried by the phase difference between the counter propagating laser beams. Using a small misalignment of the interferometer, orthogonal to the plane of the tilt, a bimodal (or two-fringe) pattern is induced in the beam's transverse power distribution. By tracking the mean of such a distribution, using a split detector, a sensitive measurement of the phase is performed. With 1.2 mW of continuous-wave laser power, the technique has a shot noise limited sensitivity of 56 frad/$\sqrt{\mbox{Hz}}$, and a measured noise floor of 200 frad/$\sqrt{\mbox{Hz}}$ for tilt frequencies above 2 Hz. A tilt of 200 frad corresponds to a differential displacement of 4.0 fm in our setup. The novelty of the protocol relies on signal amplification due to the misalignment, and on good performance at low frequencies. A noise floor of about 70 prad/$\sqrt{\mbox{Hz}}$ is observed between 2 and 100 mHz.
References in corpus (22)
- Advances in atomic force microscopy
- Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification
- Nonperturbative theory of weak pre- and post-selected measurements
- Experimental observation of the spin Hall effect of light on a nano-metal film via weak measurements
- Amplification of Angular Rotations Using Weak Measurements
- Optimizing the Signal to Noise Ratio of a Beam Deflection Measurement with Interferometric Weak Values
- Precision frequency measurements with interferometric weak values
- Weak Values Technique for Velocity Measurements
- Continuous phase amplification with a Sagnac interferometer
- Experimentally quantifying the advantages of weak-value-based metrology
- Observation of the Imbert-Fedorov effect via weak value amplification
- A Precision Angle Sensor using an Optical Lever inside a Sagnac Interferometer
- Measurement of sub-pulse-width temporal delays via spectral interference induced by weak value amplification
- Enhancement of the sensitivity of a temperature sensor based on Fiber Bragg Gratings via weak value amplification
- Picoradian deflection measurement with an interferometric quasi-autocollimator using weak value amplification
- Upper Limit on Gravitational Wave Backgrounds at 0.2 Hz with Torsion-bar Antenna
- Can Anomalous Amplification be Attained Without Postselection?
- Highly stable polarization independent Mach-Zehnder interferometer
- Observation of spectral interference for any path difference in an interferometer
- Anomalous Amplification of a Homodyne signal via Almost-Balanced Weak Values
- Complementary weak-value amplification with concatenated postselections
- Practical Advantages of Almost-Balanced-Weak-Values Metrological Techniques
Cited by in corpus (13)
- Quantum Advantage in Postselected Metrology
- Negative quasiprobabilities enhance phase estimation in quantum-optics experiment
- Toward Ultra-high Sensitivity in Weak Value Amplification
- Weak-value-amplification analysis beyond the AAV limit of weak measurements
- Geometric phases and the Sagnac effect: Foundational aspects and sensing applications
- Investigating the Effects of the Interaction Intensity in a Weak Measurement
- Quantum-Enhanced Sensing from Hyper-Entanglement
- Progress and Perspectives on Weak-value Amplification
- Noise suppression in inverse weak value based phase detection
- Gravitational sensing with weak value based optical sensors
- Enhanced on-chip frequency measurement using weak value amplification
- Quality analysis for precision metrology based on joint weak measurements without discarding readout data
- Weak-Value Amplification for Longitudinal Phase Measurements Approaching the Shot-Noise Limit Characterized by Allan Variance