Complementary weak-value amplification with concatenated postselections
arXiv:1606.02249 · doi:10.1103/PhysRevA.94.043825
Abstract
We measure a transverse momentum kick in a Sagnac interferometer using weak-value amplification with two postselections. The first postselection is controlled by a polarization dependent phase mismatch between both paths of a Sagnac interferometer and the second postselection is controlled by a polarizer at the exit port. By monitoring the darkport of the interferometer, we study the complementary amplification of the concatenated postselections, where the polarization extinction ratio is greater than the contrast of the spatial interference. In this case, we find an improvement in the amplification of the signal of interest by introducing a second postselection to the system.
References in corpus (24)
- Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification
- Direct Measurement of the Quantum Wavefunction
- Experimental joint weak measurement on a photon pair as a probe of Hardy's Paradox
- Direct measurement of general quantum states using weak measurement
- Technical advantages for weak value amplification: When less is more
- Experimental Realization of the Quantum Box Problem
- Precision frequency measurements with interferometric weak values
- Observation of a quantum Cheshire Cat in a matter wave interferometer experiment
- Weak Values Technique for Velocity Measurements
- Continuous phase amplification with a Sagnac interferometer
- Experimentally quantifying the advantages of weak-value-based metrology
- Improving the precision of weak measurements by postselection measurement
- Weak Measurements Beyond the Aharonov-Albert-Vaidman Formalism
- All-order evaluation of weak measurements: --- The cases of an operator which satisfies the property ---
- Interferometric weak value deflections: quantum and classical treatments
- Ultra-sensitive phase estimation with white light
- On Amplification by Weak Measurement
- Observing angular deviations in light beam reflection via weak measurements
- Can Anomalous Amplification be Attained Without Postselection?
- 'Quantum Cheshire Cat' as Simple Quantum Interference
- Compressive Wavefront Sensing with Weak Values
- Weak measurement with orthogonal pre-selection and post-selection
- Measurement of Pancharatnam's phase by robust interferometric and polarimetric methods
- Weak values and weak coupling maximizing the output of weak measurements
Cited by in corpus (5)
- Ultrasensitive Inverse Weak-Value Tilt Meter
- Weak-value-amplification analysis beyond the AAV limit of weak measurements
- Anomalous Amplification of a Homodyne signal via Almost-Balanced Weak Values
- Practical Advantages of Almost-Balanced-Weak-Values Metrological Techniques
- Phonon maser stimulated by spin post-selection