Noise suppression in inverse weak value based phase detection
arXiv:1707.03122 · doi:10.1007/s40509-017-0145-7
Abstract
We examine the effect of different sources of technical noise on inverse weak value-based precision phase measurements. We find that this type of measurement is similarly robust to technical noise as related experiments in the weak value regime. In particular, the measurements considered here are robust to additive Gaussian white noise and angular jitter noise commonly encountered in optical experiments. Additionally, we show the same techniques used for precision phase measurement can be used with the same technical advantages for optical frequency measurements.
arXiv comment6 pages, 4 figures
References in corpus (26)
- Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification
- Colloquium: Understanding Quantum Weak Values: Basics and Applications
- Nonperturbative theory of weak pre- and post-selected measurements
- Experimental observation of the spin Hall effect of light on a nano-metal film via weak measurements
- Technical advantages for weak value amplification: When less is more
- Amplification of Angular Rotations Using Weak Measurements
- Weak Measurements of Light Chirality with a Plasmonic Slit
- Optimizing the Signal to Noise Ratio of a Beam Deflection Measurement with Interferometric Weak Values
- Precision frequency measurements with interferometric weak values
- Weak Values Technique for Velocity Measurements
- Continuous phase amplification with a Sagnac interferometer
- Measuring ultrasmall time delays of light by joint weak measurements
- When amplification with weak values fails to suppress technical noise
- Improving the precision of weak measurements by postselection measurement
- Experimentally quantifying the advantages of weak-value-based metrology
- Entanglement-assisted weak value amplification
- Strengthening weak value amplification with recycled photons
- Power-recycled weak-value-based metrology
- Interferometric weak value deflections: quantum and classical treatments
- A Precision Angle Sensor using an Optical Lever inside a Sagnac Interferometer
- Measurement of sub-pulse-width temporal delays via spectral interference induced by weak value amplification
- Weak-value amplification as an optimal metrological protocol
- Enhancement of the sensitivity of a temperature sensor based on Fiber Bragg Gratings via weak value amplification
- Weak-Value Amplification of light deflection by a dark atomic ensemble
- Protecting weak measurements against systematic errors
- Ultrasensitive Inverse Weak-Value Tilt Meter