Quality analysis for precision metrology based on joint weak measurements without discarding readout data
arXiv:2207.03668 · doi:10.1088/1751-8121/acd919
Abstract
We present a theoretical analysis for the metrology quality of joint weak measurements (JWM), in close comparison with the weak-value-amplification (WVA) technique. We point out that the difference probability function employed in the JWM scheme cannot be used to calculate the uncertainty variance and Fisher information (FI). In order to carry out the metrological precision, we reformulate the problem in terms of difference-combined stochastic variables, which makes all calculations well defined. We reveal that, in general, the metrological precision of the JWM scheme cannot reach that indicated by the total FI, despite that all the readouts are collected without discarding. We also analyze the effect of technical noise, showing that the technical noise cannot be removed by the subtracting procedure, which yet can be utilized to outperform the conventional measurement, when considering the imaginary WV measurement.
arXiv comment10 pages, 6 figures
References in corpus (34)
- Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification
- Measuring small longitudinal phase shifts: weak measurements or standard interferometry?
- Technical advantages for weak value amplification: When less is more
- Amplifying Single-Photon Nonlinearity Using Weak Measurement
- Optimizing the Signal to Noise Ratio of a Beam Deflection Measurement with Interferometric Weak Values
- Weak value amplification is suboptimal for estimation and detection
- Precision frequency measurements with interferometric weak values
- Precision metrology using weak measurements
- Continuous phase amplification with a Sagnac interferometer
- How the result of a single coin toss can turn out to be 100 heads
- Measuring ultrasmall time delays of light by joint weak measurements
- When amplification with weak values fails to suppress technical noise
- Weak Value Amplification Can Outperform Conventional Measurement in the Presence of Detector Saturation
- Information amplification via postselection: A parameter estimation perspective
- Improving the precision of weak measurements by postselection measurement
- Quantum measurements with preselection and postselection
- Using technical noise to increase the signal-to-noise ratio, via imaginary weak values
- Approaching quantum-limited metrology with imperfect detectors by using weak-value amplification
- Strengthening weak value amplification with recycled photons
- All-order evaluation of weak measurements: --- The cases of an operator which satisfies the property ---
- On Amplification by Weak Measurement
- Weak value amplification in a shot-noise limited interferometer
- Protecting weak measurements against systematic errors
- Enhanced weak-value amplification via photon recycling
- Ultra-small phase estimation via weak measurement technique with postselection
- Can Anomalous Amplification be Attained Without Postselection?
- Toward Ultra-high Sensitivity in Weak Value Amplification
- Ultrasensitive Inverse Weak-Value Tilt Meter
- Heisenberg scaling with weak measurement: A quantum state discrimination point of view
- Weak-value-amplification analysis beyond the AAV limit of weak measurements
- Heisenberg-limited metrology with information recycling
- Simple understanding of quantum weak values
- Anomalous Amplification of a Homodyne signal via Almost-Balanced Weak Values
- Practical Advantages of Almost-Balanced-Weak-Values Metrological Techniques